Information based on query as of Wednesday, August 14, 2024.
Permit Information
Permit NumberMIS18-00084
StatusFinaled
Name NICHOLAS JONES
Site Address 350 N MILWAUKEE ST Unit: 2012
Project NameBTS - #2012
Customer Number 
ePlanReviewNo
Description
neneed plumbing and mechanical inspections for the occupancy permit and C of O
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled  5/10/2018 PASS
permits issued
PLM-Final3/16/20183/16/20183/16/2018PPASS
DetailsBill VanDegrift
Nicholas Phone #: ###-#### permits pulled
DOC - Permit Finaled3/16/20183/16/20183/16/2018PPASS
DetailsBill VanDegrift
Nicholas Phone #: ###-#### permit pulled
MEC-Final3/16/20183/16/20183/16/2018PPASS
DetailsBill VanDegrift
Nicholas Phone #: ###-#### mec permit pulled
PLM-Final3/13/20183/15/20183/15/2018AFAIL
DetailsDan Ediger
NIcholas Phone #: ###-#### for restaurant occupancy
The double check and rp are run in series.
1. The carbonator must have a dedicated rp backflow assembly.
2. The ice tea machine must be served by a rp backflow assembly.
3. Install airgaps on both rp's and pipe to the floor sink.
4. Support the backflow assemblies on the outlet side.
5. The plumber must pull a permit and schedule an inspection.
6. If the ice maker has a pre-filter installed then it must be protected by a double check.
MEC-Final3/13/20183/15/20183/15/2018AFAIL
DetailsBrian Scoles
NIcholas Phone #: ###-#### for restaurant occupancy- need to tether all appliances discussed- needs splash shield installed between fryer and open flame top- need mech or plumbing permit pulled for gas work- need air balance report- Nichalos knows about these issues
Application received  3/12/2018  
Issue Misc Permit............  3/12/2018 DONE