Permit Information
Permit NumberNAF19-00084
StatusFinaled
Name JEFFREY LIKES
Site Address 6742 GLENWOOD
Project NameGAR2019-0201/BLDFY2019-0201
Customer Number 
ePlanReviewNo
Description
(Vanilla Finish-6742 Glenwood) Remodel of existing space in a strip mall to create 3 separate spaces. Work includes demolition of interior walls, addition of separate entrances in the front and rear of each space as well as the addition of new restrooms. The building has fire sprinklers. Any work on the fire sprinkler or fire alarm system will require separate permits. No occupancy is granted on this permit. **MS**
09.03.2019-Plan mod updates addresses for all three suites and separates into 3 separate permits. NAF19-00072; NAF19-00083; NAF19-00084.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Sprinkler Rough-in/Hydro1/13/20201/13/20201/13/2020PCANC
DetailsTroy Cobbley
Wrong inspection type scheduled.
INSP-Final1/13/20201/13/20201/13/2020PDONE
DetailsTroy Cobbley
Life safety passed.
DOC - Permit Finaled  1/13/2020 DONE
Passing final per Troy C 1/13/20
INSP-Final12/26/201912/27/201912/27/2019AFAIL
DetailsJim Page
Tenant needs to get seperate permit for occupancy, this permit is for vanilla shell only, no occpancy for this permit is stated in project description. East area of tenant (rear storage area) space has 2 sprinkler heads that are less than 6 foot apart, a minimum of 6 feet between heads is required per NFPA 13, verify sprinkler head spacing in storage area as well, possible overspaced sprinkler head. Insulation barrier paper is blocking/resting on numerous upright heads, insulation barrier needs adjusted for proper coverage of fire sprinkler heads as well as providing the minimum 1 inch clearance above head as required by NFPA 13. Area next to main entry, northside of door has a pocket created by plywood, fire sprinkler addition required to be code compliant, any and all modifications to fire sprinkler system will require a seperate permit. Provide annual inspection for fire extinguisher as discussed.

Call for access Phone #: 7025055936 >> Inspection requested via mobile web by Inis Smith
Permit Ready to Issue  10/28/2019 DONE
plan mod #2 approved
CHANGE STATUS TO (ISS)  10/28/2019 DONE
Plan mod #2 approved
Miscellaneous action  10/28/2019 DONE
emailed Shelley that plan mod #2 is ready
Staff review10/17/201910/17/201910/25/2019 DONE
DetailsErika Akin
Approved for vanilla TI. (Review TIme: 1-hr) Separate permit required for tenant and Certificate of Occuapncy. 10/31 (plan mod) Vanilla TI, GAR2###-####
Plan Modification Accepted  10/17/2019 DONE
Plan mod
Staff review9/11/20199/11/20199/17/2019 DONE
DetailsMark Scharfen
plan mod minimum 1 hr fee-no review required
Plan assigned to (Scharfen)9/11/2019 9/17/2019 DONE
DetailsMark Scharfen
Permit Ready to Issue  9/17/2019 DONE
CHANGE STATUS TO (ISS)  9/17/2019 DONE
plan mod
Telephone call  9/17/2019 DONE
emailed Shelley that the plan mod was complete
Plan Modification Accepted  9/11/2019 DONE
plan mod in e plan-assign and staff reviewed to MS
Permit Ready to Issue  9/4/2019 DONE
Issue and Courier  9/4/2019 DONE
emailed Shelley
Staff review8/23/20198/23/20199/3/2019 PASS
DetailsMark Scharfen
09.03.2019-Completed fire review. rev_fire 09.03.2019.pdf uploaded.
Plan assigned to (Scharfen)8/23/2019 9/3/2019 PASS
DetailsMark Scharfen
09.03.2019-Completed fire review. Uploaded rev_fire 09.03.2019.pdf
PLANS/APPL TAKEN TO FRONT DESK  9/3/2019 PASS
DetailsMark Scharfen
09.03.2019-Completed fire review. Uploaded rev_fire 09.03.2019.pdf
Application received  8/23/2019  
Miscellaneous action  8/23/2019 DONE
emailed Shelley permit app and NAF#
Plan assigned to (Erika)10/17/2019   DONE
DetailsErika Akin
(Review Time 1-hr) plan mod