Final | 11/1/2001 | 11/1/2001 | 11/1/2001 | P | PASS |
Bill VanDegrift
|
|
|
###-#### BOB final ok with sprinkler permit still open 11/1/2001 1:55:11 PM
|
DOC - Permit Finaled | 11/1/2001 | 11/1/2001 | 11/1/2001 | P | PASS |
Bill VanDegrift
|
|
|
Finaled by inspector at 11/1/2001 2:01:02 PM
|
Final | 10/30/2001 | 10/31/2001 | 10/31/2001 | A | NR |
Bill VanDegrift
|
|
|
Scheduled by a contractor via Hello! on 10/30/2001 at 14:43:47. Contact: ###-####. sprinkler permit required prior to final 10/31/2001 10:16:20 AM
|
Plumbing Rough-in | 8/10/2001 | 8/13/2001 | 8/13/2001 | A | PASS |
Bill VanDegrift
|
|
|
Scheduled by a contractor via Hello! on 08/10/2001 at 16:38:48. Contact: ###-####.
|
Plumbing Rough-in | 8/7/2001 | 8/7/2001 | 8/7/2001 | P | FAIL |
Bill VanDegrift
|
|
|
Scheduled by a contractor via Hello! on 08/07/2001 at 08:46:47. Contact: ###-####. water heater piping and washer trap in outside wall, R-13 required behind washer trap prior to reinspection, PEX wih in 12" of recessed light fixture, nail plates required where piping is within 1" of face of stud or plate. 8/7/2001 3:02:13 PM
|
Plumbing Rough-in | 7/31/2001 | 8/1/2001 | 8/1/2001 | P | CANC |
Bill VanDegrift
|
|
|
Scheduled by a contractor via Hello! on 07/31/2001 at 14:18:26. Contact: ###-####.--cancel per bob
|
Groundwork | 6/21/2001 | 6/21/2001 | 6/21/2001 | P | PART |
Bill VanDegrift
|
|
|
Scheduled by a contractor via Hello! on 06/21/2001 at 09:18:53. Contact: ###-####. gw ok with piping penatrating the floor wrapped 6/21/2001 1:45:51 PM 6/21/2001 1:46:23 PM
|
Application received | | | 6/21/2001 | | |
|
|
|
|
Issue & PRINT permit | | | 6/21/2001 | | DONE |
|
|
|
|