Final | 12/26/2001 | 12/27/2001 | 12/27/2001 | A | PASS |
Bill VanDegrift
|
|
|
ROBERT ###-####
|
DOC - Permit Finaled | 12/27/2001 | 12/27/2001 | 12/27/2001 | A | PASS |
Bill VanDegrift
|
|
|
Finaled by inspector at 12/27/2001 8:53:22 AM
|
PLM-Aging Inspection | 12/25/2001 | 12/25/2001 | 12/25/2001 | | NR |
Bill VanDegrift
|
|
|
|
Plumbing Rough-in | 10/24/2001 | 10/25/2001 | 10/25/2001 | A | PART |
Bill VanDegrift
|
|
|
ROBERT ###-#### west side ri ok with water lines hung in crawlspace, and 2 clamps on the service connection. 10/25/2001 8:41:08 AM
|
Plumbing Rough-in | 10/25/2001 | 10/25/2001 | 10/25/2001 | P | PASS |
Bill VanDegrift
|
|
|
Scheduled by Inspector: 330 On 10/25/2001 8:39:58 AM east side
|
Plumbing Rough-in | 10/24/2001 | 10/24/2001 | 10/24/2001 | P | CANC |
Bill VanDegrift
|
|
|
###-#### ROBERT
|
Plumbing Rough-in | 10/22/2001 | 10/23/2001 | 10/23/2001 | A | FAIL |
Bill VanDegrift
|
|
|
Scheduled by a contractor via Hello! on 10/22/2001 at 19:49:45. Contact: ###-####. turn vent santees the right dirrection, hang waste every 4', water every 32", NO WASTE CONNECTION ALLOWED ON A CLOSET ARM, ROLL VENTS ABOVE FLOWLINE, C.O. REQUIRED ON ISLAND SINK VENT, TESTS REQUIRED. 10/23/2001 9:44:24 AM
|
Application received | | | 10/12/2001 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 10/12/2001 | | DONE |
|
|
|
|