Telephone Call | | | 6/10/2004 | | DONE |
|
|
|
|
DOC - Permit Finaled | 6/27/2003 | 6/27/2003 | 6/27/2003 | P | PASS |
Jim Johnson
|
|
|
Finaled by inspector at 6/27/2003 4:07:44 PM
|
Final | 6/27/2003 | 6/27/2003 | 6/27/2003 | P | PASS |
Jim Johnson
|
|
|
rob; Phone #: ###-#### Internet Inspection Request from: Annette Moore
|
Final | 6/26/2003 | 6/26/2003 | 6/26/2003 | P | PART |
Jim Johnson
|
|
|
Scheduled by a contractor via Hello! on 6/26/2003 at 7:34:35 AM. Contact: ###-####. need R.P. for smoke house unit,s caulk all fixtures to wall provide air gap on case drain,s to hub & floor sinks remove test plug from grease interceptor vent need to provide protective cover for p-trap and hot water side under handicapp lav in rest room also bolt down gas tight lides to grease interceptor contractor to recall when ready 6/26/2003 5:00:58 PM
|
PLM-Aging Inspection | 4/28/2003 | 4/28/2003 | 4/28/2003 | | PASS |
Jim Johnson
|
|
|
still working on project 4/28/2003 8:30:05 AM
|
Plumbing Rough-in | 2/25/2003 | 2/25/2003 | 2/25/2003 | P | PASS |
Jim Johnson
|
|
|
Scheduled by a contractor via Hello! on 2/25/2003 at 7:39:37 AM. Contact: ###-####.
|
Plumbing Rough-in | 2/20/2003 | 2/20/2003 | 2/20/2003 | P | FAIL |
Jim Johnson
|
|
|
Scheduled by a contractor via Hello! on 2/20/2003 at 8:43:20 AM. Contact: ###-####. air test on sanitary sewer failed need to find vent for trench drain and tie in to vent system 2/21/2003 8:36:24 AM
|
PLM-Aging Inspection | 1/22/2003 | 1/22/2003 | 1/22/2003 | | PASS |
Jim Johnson
|
|
|
called contractor project still under construction getting ready to start rough-in 1/22/2003 11:32:28 AM
|
Plumbing Rough-in | 11/12/2002 | 11/12/2002 | 11/12/2002 | A | PART |
Jim Johnson
|
|
|
Scheduled by a contractor via Hello! on 11/12/2002 at 06:23:00. Contact: ###-####.need to test grease intercepter and plumber missed floor sink in groundwork need to install trap and vent and retest ground work ok to cover portion of ground work that was tested contractor to recall when ready 11/12/2002 12:02:32 PM
|
Groundwork | 11/12/2002 | 11/12/2002 | 11/12/2002 | P | PASS |
Jim Johnson
|
|
|
|
Plumbing Rough-in | 11/7/2002 | 11/7/2002 | 11/7/2002 | P | PART |
Jim Johnson
|
|
|
###-#### back side of grease interceptor and sanitary sewer system in side bulding test ok ok to cover grease system piping and grease interceptor still need to be tested 11/7/2002 4:42:24 PM
|
Application received | | | 10/18/2002 | | |
|
|
|
|
Issue & PRINT permit | | | 10/18/2002 | | DONE |
|
|
|
|