Final | 7/7/2005 | 7/8/2005 | 7/8/2005 | A | PASS |
Daryl Spivey
|
|
|
mark; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
(F) Reprint permit | | | 6/28/2005 | | DONE |
|
|
|
|
Final | 6/20/2005 | 6/21/2005 | 6/21/2005 | A | FAIL |
Bill VanDegrift
|
|
|
devine cell ###-#### --call 1st before insp calk lav and toilet. unions required with in 12" of the water heater, cold water side the union needs to be between the water heater and the shut off valve. update the permit, all we have a permit for is the sewer and water services outside.
|
Plumbing Rough-in | 6/10/2004 | 6/10/2004 | 6/10/2004 | P | PASS |
Lee Rice
|
|
|
cindy or mark; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
Other | 5/14/2004 | 5/14/2004 | 5/14/2004 | P | PART |
Bill VanDegrift
|
|
|
needs to update his permit, had a ri conference, needs to move water piping and washer box inside exterior walls, vent washer box with 2" for cross sectional area requirements, use a drainage fitting at the top of his waste stack, verify 18" requirement for spark or glow at water heater, use frost free hose bibs, 2" waste to the kitchen sink, and turn the vent fitting at the shower around.
|
Water and/or Sewer | 10/13/2003 | 10/13/2003 | 10/13/2003 | P | PASS |
Bill VanDegrift
|
|
|
###-#### MARK this is just the stubs into the building 10/13/2003 8:58:48 AM
|
Water and/or Sewer | 9/26/2003 | 9/30/2003 | 9/30/2003 | P | PART |
Bill VanDegrift
|
|
|
mark ; Phone #: ###-#### Internet Inspection Request from: Annette Moore ok to bed 9/30/2003 10:54:24 AM
|
Water and/or Sewer | 9/26/2003 | 9/29/2003 | 9/29/2003 | A | NR |
Bill VanDegrift
|
|
|
###-#### mark should have been canc. needs bedding and testing 9/29/2003 9:14:01 AM
|
Issue PAID IN FULL permit | | | 9/26/2003 | | DONE |
|
|
|
|
(F) Reprint permit | | | 9/26/2003 | | DONE |
|
|
|
|
Application received | | | 9/26/2003 | | |
|
|
|
|