Water and/or Sewer | 10/28/2004 | 10/28/2004 | 10/28/2004 | P | CANC |
Jim Johnson
|
|
|
someone will be there Internet Inspection Request from: Roger Patterson
|
Final | 10/28/2004 | 10/28/2004 | 10/28/2004 | P | PASS |
Jim Johnson
|
|
|
|
DOC - Permit Finaled | 10/28/2004 | 10/28/2004 | 10/28/2004 | P | PASS |
Jim Johnson
|
|
|
Finaled by inspector at 10/28/2004 1:19:13 PM
|
Groundwork | 8/19/2004 | 8/20/2004 | 8/20/2004 | A | PASS |
Jim Johnson
|
|
|
jim; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
Plumbing Rough-in | 7/15/2004 | 7/15/2004 | 7/15/2004 | P | FAIL |
Jim Johnson
|
|
|
roger; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie unable to do inspection a stop work notice has been issued by structural 7/15/2004 2:32:55 PM
|
Plumbing Rough-in | 7/13/2004 | 7/13/2004 | 7/13/2004 | P | FAIL |
Jim Johnson
|
|
|
roger; Phone #: ###-#### Internet Inspection Request from: Annette Moore need to repair damaged 1 inch pex water line and correct leak at 4 inch mission band from abs to cast in ground work called roger with A-1 will recall when ready 7/13/2004 2:04:01 PM
|
Plumbing Rough-in | 7/8/2004 | 7/9/2004 | 7/9/2004 | A | FAIL |
Jim Johnson
|
|
|
Roger; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes need to correct damaged pipe to washer box , vent down staires floor drain, need cleanouts at base of stack,s need to meet cross- sectional venting , support abs every 4 feet, support back hydrant, need to provide protection for piping through concrete wall test all DWV piping meet with plumber on job site contractor to recall when ready 7/9/2004 12:07:16 PM
|
Application received | | | 7/8/2004 | | |
|
|
|
|
Issue permit | | | 7/8/2004 | | |
|
|
|
|