First Notice | 2/15/2007 | 2/15/2007 | 3/15/2007 | | DONE |
Eric Strole
|
|
|
This permit finaled on the web by raul castanon
|
Final | 2/15/2007 | 2/15/2007 | 2/15/2007 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-####
|
Final | 1/16/2007 | 1/17/2007 | 1/17/2007 | A | FAIL |
Eric Strole
|
|
|
Phone #: ###-####-same as plm06-01802
|
PLM-Aging Inspection | 1/3/2007 | 1/3/2007 | 1/3/2007 | | NR |
Eric Strole
|
|
|
wip
|
Plumbing Rough-in | 10/25/2006 | 10/26/2006 | 10/26/2006 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon
|
Water and/or Sewer | 6/28/2006 | 6/28/2006 | 6/28/2006 | P | PASS |
Gerry Varner
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon
|
Groundwork | 6/20/2006 | 6/21/2006 | 6/21/2006 | A | PASS |
Gerry Varner
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon
|
Groundwork | 6/19/2006 | 6/20/2006 | 6/20/2006 | A | PART |
Gerry Varner
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon add c.o.'s
|
Application received | | | 5/31/2006 | | DONE |
|
|
|
This permit was created on the web by raul castanon
|