Water and/or Sewer | 6/18/2008 | 6/18/2008 | 6/18/2008 | P | PASS |
Eric Strole
|
|
|
|
DOC - Permit Finaled | 6/18/2008 | 6/18/2008 | 6/18/2008 | P | PASS |
Eric Strole
|
|
|
|
PLM-Aging Inspection | 5/28/2008 | 5/28/2008 | 5/28/2008 | | PASS |
Eric Strole
|
|
|
|
Roof Drains | 3/27/2008 | 3/28/2008 | 3/28/2008 | A | PASS |
Jim Johnson
|
|
|
brian NOte: 10:00 am if possible Phone #: ###-#### visual on storm drain extension to building with cleanout,s and approved fitting,s
|
Roof Drains | 3/26/2008 | 3/27/2008 | 3/27/2008 | A | PART |
Jim Johnson
|
|
|
john Phone #: ###-#### visual on roof drain extension,s up to building with clean out,s first seven location,s on east side of building all with approved directional fitting,s
|
PLM-Aging Inspection | 2/18/2008 | 2/18/2008 | 2/19/2008 | | PASS |
Eric Strole
|
|
|
|
PLM-Aging Inspection | 12/17/2007 | 12/18/2007 | 12/18/2007 | P | PASS |
Eric Strole
|
|
|
|
PLM-Aging Inspection | 12/17/2007 | 12/17/2007 | 12/17/2007 | | CANC |
Lee Rice
|
|
|
|
PLM-Aging Inspection | 10/15/2007 | 10/15/2007 | 10/15/2007 | | PASS |
Eric Strole
|
|
|
|
PLM-Aging Inspection | 8/13/2007 | 8/13/2007 | 8/13/2007 | | PASS |
Eric Strole
|
|
|
|
Water and/or Sewer | 6/11/2007 | 6/12/2007 | 6/12/2007 | A | CANC |
Eric Strole
|
|
|
John; Phone #: ###-#### Internet Inspection Request from: Hattie James
|
Water and/or Sewer | 5/23/2007 | 5/29/2007 | 5/29/2007 | A | PART |
Eric Strole
|
|
|
Boyd; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt-camera of storm drains, looks good, they will flush lines.
|
Storm Drains | 5/22/2007 | 5/23/2007 | 5/23/2007 | A | PART |
Eric Strole
|
|
|
Lloyd; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt-air test on storm drains pass.
|
(F) Reprint permit | | | 5/22/2007 | | DONE |
|
|
|
|
Water and/or Sewer | 5/18/2007 | 5/18/2007 | 5/18/2007 | A | PART |
Eric Strole
|
|
|
water line test pass.
|
Other | 5/17/2007 | 5/17/2007 | 5/17/2007 | P | FAIL |
Eric Strole
|
|
|
this was a conferance with lee, eric, cascade pipeline & general of job on storm drains, need to replace tee's with directional fittings, test system, camera or man drill storm drains.
|
Water and/or Sewer | 5/17/2007 | 5/17/2007 | 5/17/2007 | A | PART |
Eric Strole
|
|
|
water line ok to cover, still needs tested.
|
Other | 5/17/2007 | 5/17/2007 | 5/17/2007 | A | FAIL |
Eric Strole
|
|
|
this was a conferance on roof drain lines in the under ground, ther was never any inspections, have to change out tees & use directional fittings, there are 8 tees that i am aware off, they will bring out pictures of work done in ground, also expose water line connection from copper to pvc.
|
Plumbing Rough-in | 5/16/2007 | 5/17/2007 | 5/17/2007 | A | CANC |
Eric Strole
|
|
|
Lloyd ; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
(F) Reprint permit | | | 5/14/2007 | | DONE |
|
|
|
|
Water and/or Sewer | 4/26/2007 | 4/26/2007 | 4/26/2007 | A | PART |
Eric Strole
|
|
|
6" & 4" sewer & sewer test pass.
|
Final | 4/25/2007 | 4/26/2007 | 4/26/2007 | A | CANC |
Eric Strole
|
|
|
john - for testing ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
|
Water and/or Sewer | 4/19/2007 | 4/20/2007 | 4/20/2007 | A | PART |
Eric Strole
|
|
|
John; Phone #: ###-#### Internet Inspection Request from: Stacie Backus-4" & 6" sewer ok to cover, still needs tested.
|
Water and/or Sewer | 4/19/2007 | 4/19/2007 | 4/19/2007 | P | PART |
Eric Strole
|
|
|
this was a conferance on sewer line.
|
Application received | | | 4/13/2007 | | |
|
|
|
|
Issue & PRINT permit | | | 4/13/2007 | | DONE |
|
|
|
|
Issue & PRINT permit | | | 4/13/2007 | | DONE |
|
|
|
|
First Notice | 6/18/2008 | 6/18/2008 | | | |
Eric Strole
|
|
|
|