Telephone call | | | 12/12/2011 | | DONE |
Tisha Gallop
|
|
|
per bob A. 2 hr admin fee to reopen job (if new contractor start new permit number).
|
PLM-Aging Inspection | 12/8/2008 | 12/8/2008 | 12/8/2008 | | PASS |
Eric Strole
|
|
|
|
DOC - Permit Expired | 12/8/2008 | 12/8/2008 | 12/8/2008 | P | PASS |
Eric Strole
|
|
|
|
PLM-Aging Inspection | 10/6/2008 | 10/6/2008 | 10/6/2008 | | PASS |
Eric Strole
|
|
|
|
PLM-Aging Inspection | 8/4/2008 | 8/4/2008 | 8/4/2008 | | PASS |
Eric Strole
|
|
|
|
Plumbing Rough-in | 6/2/2008 | 6/2/2008 | 6/2/2008 | P | PASS |
Jim Johnson
|
|
|
Re-inspection. Phone #: ###-#### Internet Inspection Request from: raul castanon
|
Plumbing Rough-in | 5/28/2008 | 5/28/2008 | 5/28/2008 | P | FAIL |
Eric Strole
|
|
|
Lot 8 reinspection. Phone #: ###-#### Internet Inspection Request from: raul castanon-dwv test failed (leak under tub ground flr, south west unit) fix reverse grade on kitchen sink vent (south east unit ground flr)
|
Plumbing Rough-in | 5/20/2008 | 5/20/2008 | 5/20/2008 | P | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon-dwv test failed(water only part way on 2nd flr)need to use approved fitting for wash basin (2nd flr) 1st flr kitchen sink vent in overhead backgraded.
|
Plumbing Rough-in | 5/12/2008 | 5/12/2008 | 5/12/2008 | P | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon- dwv test failed, cannot use 2x1 1/2 y for trap arm (weir of trap cannot be above point of vent) need some overhead straping on dwv.
|
PLM-Aging Inspection | 3/25/2008 | 3/25/2008 | 3/25/2008 | | PASS |
Eric Strole
|
|
|
|
PLM-Aging Inspection | 1/23/2008 | 1/23/2008 | 1/23/2008 | | PASS |
Eric Strole
|
|
|
|
PLM-Aging Inspection | 11/22/2007 | 11/22/2007 | 11/23/2007 | | NR |
Eric Strole
|
|
|
|
Water and/or Sewer | 9/18/2007 | 9/18/2007 | 9/18/2007 | P | PASS |
Eric Strole
|
|
|
Carlos Phone #: ###-#### Internet Inspection Request from: raul castanon
|
Water and/or Sewer | 9/14/2007 | 9/17/2007 | 9/17/2007 | P | FAIL |
Eric Strole
|
|
|
Carlos Phone #: ###-#### Internet Inspection Request from: raul castanon-need to use proper transition between pvc to abs.
|
Water and/or Sewer | 9/14/2007 | 9/14/2007 | 9/14/2007 | P | CANC |
Eric Strole
|
|
|
Carlos Phone #: ###-#### Internet Inspection Request from: raul castanon Inspection cancelled from web by: raul castanon
|
Groundwork | 9/12/2007 | 9/12/2007 | 9/12/2007 | P | PASS |
Eric Strole
|
|
|
Carlos Phone #: ###-#### Internet Inspection Request from: raul castanon
|
Application received | | | 9/6/2007 | | DONE |
|
|
|
This permit was created on the web by raul castanon
|