Final | 10/13/2008 | 10/14/2008 | 10/14/2008 | P | PASS |
Jim Johnson
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon
|
Final | 10/7/2008 | 10/7/2008 | 10/7/2008 | P | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon-unions for dbca need to be accessible, caulk all fixtures, need airgap on t&p, install roff drain & overflow per chapter 11 2003 upc
|
Final | 9/10/2008 | 9/10/2008 | 9/10/2008 | P | FAIL |
Jim Johnson
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon need to have premise protection (double check ) tested and certified need to correct reverse grade on trap arm to drinking fountain need water to drinking fountain need to power up water heater and adjust lav faucet,s to 120 degree water need to caulk mop sink to floor and wall need to caulk water closet,s to floor need to test roof drain and provide secondary roof drainage as per U P C 1101.11.2.1
|
Plumbing Rough-in | 7/30/2008 | 7/31/2008 | 7/31/2008 | A | PASS |
Jim Johnson
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon
|
Plumbing Rough-in | 7/23/2008 | 7/24/2008 | 7/24/2008 | A | NR |
Jim Johnson
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon not ready
|
Plumbing Rough-in | 7/21/2008 | 7/22/2008 | 7/22/2008 | A | FAIL |
Jim Johnson
|
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon need to support D W V abs piping every 4 feet as per table 3-2 need meet cross-sectional area on venting for 4 inch building drain called contractor will recall when ready
|
PLM-Aging Inspection | 7/11/2008 | 7/11/2008 | 7/11/2008 | | PASS |
Jim Johnson
|
|
|
under construction
|
PLM-Aging Inspection | 4/29/2008 | 4/29/2008 | 4/29/2008 | | CANC |
Jim Johnson
|
|
|
Inspection cancelled from web by: raul castanon
|
Groundwork | 2/25/2008 | 2/25/2008 | 2/25/2008 | P | PASS |
Jim Johnson
|
|
|
Carlos Phone #: ###-#### Internet Inspection Request from: raul castanon
|
Application received | | | 2/25/2008 | | DONE |
|
|
|
This permit was created on the web by raul castanon
|
First Notice | 10/14/2008 | 10/14/2008 | | | |
Jim Johnson
|
|
|
|