Permit Information
Permit NumberPLM08-02200
StatusFinaled
Name EXCEL PLUMBING
Site Address 545 N BENJAMIN LN Unit: 155
Project NameLIFE INC
Customer Number 
ePlanReview 
Description
Install 1 double drinking fountain, 1 wash basin, 3 break sinks, 1 washer box---per initial cert of value $4,765///9-11-08 ALR
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/30/200810/30/200810/30/2008PPASS
DetailsJim Johnson
bob Phone #: ###-####
Final10/28/200810/29/200810/29/2008APART
DetailsJim Johnson
bob Phone #: ###-#### need to repipe mop sink to be installed down stream of new doudle check installed for premise protection called contractor will recall when ready oked temp.
Plumbing Rough-in9/15/20089/15/20089/15/2008PPASS
DetailsJim Johnson
Bob Phone #: ###-####
Plumbing Rough-in9/11/20089/11/20089/11/2008PFAIL
DetailsJim Johnson
bob Phone #: ###-#### need to correct 1/3 permitted length on minimum sized vent in horizontal position as per table 7-5 on two break room sink,s on 1 1/2 vent need to correct trap arm for drinking fountain vent opening shall not be below the weir of the trap need letter from architect about deleting one drinking fountain as showen on approved plan,s called Bob contractor will recall when ready
Application received  9/11/2008  
Issue permit  9/11/2008 DONE
DetailsAlexandra L. DeYoung
First Notice10/30/200810/30/2008   
DetailsJim Johnson