Permit Information
Permit NumberPLM08-02351
StatusFinaled
Name RIDGEWAY INDUSTRIAL INC
Site Address 3430 N MAPLE GROVE RD
Project Name 
Customer Number5790
ePlanReview 
Description
Plumbing Permit - Alteration: Connect to existing 2" cold water and install 1" isolation valve & copper piping to new water heater. Install new 50gallon 18kw elect. water heater with iso valves. Install 1" hot water piping from water heater to existing sinks & dishwasher. Insulate
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice11/26/200811/26/20081/29/2009 DONE
DetailsJim Johnson
Telephone call  1/29/2009 DONE
lft vm with ileen ###-#### regarding the final values for lm values differences she gave me on cov 1:55 pm - she will call back
Telephone call  1/28/2009 DONE
tlk ridgeway ###-#### regarding the final value 4:45 she will call be back tomarrow
Final11/26/200811/26/200811/26/2008PPASS
DetailsJim Johnson
no sign-off card on site
Other11/26/200811/26/200811/26/2008ADONE
DetailsEric Strole
conferance
Final11/24/200811/25/200811/25/2008APART
DetailsEric Strole
Field contact is JT Waters Phone #: ###-#### Internet Inspection Request from: Julie Klocke-discharge from dishwasher needs to go indirect & provide drainage for rpba.
Final11/20/200811/20/200811/20/2008PPART
DetailsEric Strole
need to install dbca on diswasher & rpba on coffee machine & have all backflow devices tested & certified,
Final11/19/200811/20/200811/20/2008APART
DetailsEric Strole
Contact is JT Waters Phone #: ###-#### Internet Inspection Request from: Julie Klocke-dbca for premis needs tested & certified, will meet with bill thompson in pm to see if dishwasher & coffee maker need backflow devce's.
Plumbing Rough-in10/13/200810/14/200810/14/2008APASS
DetailsEric Strole
Contact is: Steve Wortman Phone #: ###-#### Internet Inspection Request from: Julie Klocke-rough-in pass. by final dbca for premis protection needs to be tested & certified & expantion tank needs to be installed on cold side.
Application received  10/3/2008 DONE
This permit was created on the web by Julie Klocke