Final | 11/1/2011 | 11/2/2011 | 11/2/2011 | A | PASS |
Jim Johnson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Erin Whiting
|
Final | 10/26/2011 | 10/27/2011 | 10/27/2011 | A | PART |
Jim Johnson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Erin Whiting need to provide seperate water supply for chemical despencer above mop sink need to repipe trap for ice maker so trap seal is not less than two and not more than four inches need to install a vacuum breaker for washer-hose bedpan and shall be located not less than 5 feet above floor 2003 upc 603.4.19 talked to plumber on site need to recall when ready
|
Plumbing Rough-in | 8/10/2011 | 8/10/2011 | 8/10/2011 | P | PASS |
Jim Johnson
|
|
|
Inspector wanted to veiw Shower Valves after installation Phone #: ###-#### >> Inspection requested via web by Erin Whiting
|
Plumbing Rough-in | 7/5/2011 | 7/6/2011 | 7/6/2011 | A | PASS |
Jim Johnson
|
|
|
Water rough in inspection Phone #: ###-#### >> Inspection requested via web by Erin Whiting rough-in water test ok ok to cover
|
Groundwork | 6/16/2011 | 6/16/2011 | 6/16/2011 | P | PASS |
Jim Johnson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Erin Whiting
|
Application received | | | 6/16/2011 | | DONE |
|
|
|
This permit was created on the web by Erin Whiting
|
First Notice | 11/2/2011 | 11/2/2011 | | | |
Jim Johnson
|
|
|
|