Final | 7/3/2014 | 7/7/2014 | 7/7/2014 | P | PASS |
Jim Johnson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Mary LaFayette
|
Final | 6/20/2014 | 6/23/2014 | 6/23/2014 | P | PART |
Jim Johnson
|
|
|
This is for water softener and water heater. Another phone is ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette need to install shut off valve on hard water line upstream of softner connection need to provide a funnel drain on 1 1/2 drain line for softner drain to prevent spillage or flooding called contractor will recall when ready
|
Final | 6/5/2014 | 6/9/2014 | 6/9/2014 | P | FAIL |
Bill VanDegrift
|
|
|
Please inspect in PM . Alternate phone # ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette provide combustion air for water heater/furnact room, t&p drain needs to terminate downward, water softener drain requires airgap.
|
Issue PAID IN FULL permit | | | 3/31/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/31/2014 | | DONE |
|
|
|
This permit was created on the web by Mary LaFayette
|