Final | 5/20/2015 | 5/21/2015 | 5/21/2015 | A | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by robert goodson-No sign-off card posted.
|
Final | 5/13/2015 | 5/13/2015 | 5/13/2015 | P | PART |
Eric Strole
|
|
|
The Backflow inspection is going to be done by 2 Phone #: ###-#### Inspection requested via web by robert goodson-Temp final ok. All backflows still need tested.
|
Final | 5/12/2015 | 5/12/2015 | 5/12/2015 | P | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by robert goodson-Need to caulk all sinks to wall. All backflows need tested and certified. Need to install a RPBA on dishwasher. Need to install a DBCA on ice machine or show a airgap. Need tempered water of 120 degree water or less to hand sinks.( Cannot use water heater) Need airgap on T&P above mop sink.
|
Plumbing Rough-in | 4/23/2015 | 4/23/2015 | 4/23/2015 | A | PASS |
Eric Strole
|
|
|
The doors won''t be open until 830 Phone #: ###-#### Inspection requested via web by robert goodson
|
Groundwork | 3/25/2015 | 3/25/2015 | 3/25/2015 | P | CANC |
Daryl Spivey
|
|
|
Phone #: ###-#### Inspection requested via web by robert goodson
|
Groundwork | 3/25/2015 | 3/25/2015 | 3/25/2015 | P | PASS |
Daryl Spivey
|
|
|
Phone #: ###-#### Inspection requested via web by robert goodson
|
Issue PAID IN FULL permit | | | 3/25/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/25/2015 | | DONE |
|
|
|
This permit was created on the web by robert goodson
|
First Notice | 5/21/2015 | 5/21/2015 | | | |
Eric Strole
|
|
|
|