DOC - Permit Expired | 4/1/2016 | 4/1/2016 | 4/1/2016 | A | PASS |
Daryl Spivey
|
|
|
Plumber did rough in only.........ds
|
PLM-Aging Inspection | 4/1/2016 | 4/1/2016 | 4/1/2016 | | PASS |
Daryl Spivey
|
|
|
|
PLM-Aging Inspection | 1/1/2016 | 1/1/2016 | 1/4/2016 | | PART |
Bill VanDegrift
|
|
|
no calls
|
PLM-Aging Inspection | 10/2/2015 | 10/2/2015 | 10/2/2015 | | NR |
Daryl Spivey
|
|
|
wip
|
Plumbing Rough-in | 5/26/2015 | 5/26/2015 | 5/26/2015 | P | PASS |
Daryl Spivey
|
|
|
Juan Phone #: ###-#### still need to run exterior vents........ds
|
Water and/or Sewer | 5/21/2015 | 5/22/2015 | 5/22/2015 | P | CANC |
Bill VanDegrift
|
|
|
Juan Phone #: ###-#### this was a gw and rough in
|
Plumbing Rough-in | 5/22/2015 | 5/22/2015 | 5/22/2015 | P | FAIL |
Bill VanDegrift
|
|
|
Juan Phone #: ###-#### 1) kitchen sink waste may not discharge to the sump in the basement, move into joist space. 2) fixture water supply tubing may not be concealled at kitchen sink. 3) reconfigure tub and shower venting to get rid of s-trap combo in reverse orientation. 4) ok to cover the ground work.
|
Groundwork | 5/22/2015 | 5/22/2015 | 5/22/2015 | P | PART |
Bill VanDegrift
|
|
|
Juan Phone #: ###-#### gw ok to cover.
|
Issue PAID IN FULL permit | | | 5/21/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Issue PAID IN FULL permit | | | 5/21/2015 | | DONE |
|
|
|
|
Application received | | | 5/21/2015 | | |
|
|
|
|