First Notice | 7/29/2015 | 7/29/2015 | 7/27/2020 | | DONE |
Eric Strole
|
|
|
This permit finaled on the web by RM Mechanical
|
Final | 7/28/2015 | 7/29/2015 | 7/29/2015 | A | PASS |
Eric Strole
|
|
|
Eric Phone #: ###-####
|
Plumbing Rough-in | 7/22/2015 | 7/22/2015 | 7/22/2015 | P | PASS |
Eric Strole
|
|
|
|
Plumbing Rough-in | 7/21/2015 | 7/22/2015 | 7/22/2015 | A | FAIL |
Eric Strole
|
|
|
Eric Phone #: ###-####- Y 1/8 bend in the vertical for the flr drain puts your trap arm above the point of vent. Needs to be a san tee or a fixture fitting.
|
Water and/or Sewer | 7/17/2015 | 7/20/2015 | 7/20/2015 | P | PART |
Eric Strole
|
|
|
Water Line; Eric Phone #: ###-####-Test on water pass. Need to vent each urinal.
|
Issue PAID IN FULL permit | | | 7/14/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/14/2015 | | DONE |
|
|
|
This permit was created on the web by Melissa Kaae
|