Final | 11/30/2015 | 12/1/2015 | 12/1/2015 | A | PASS |
Jim Little
|
|
|
Call for access // Bill Phone #: ###-#### >fix leak at sink in garage and caulk undermount sinks from inside, then ok.
|
Plumbing Rough-in | 10/2/2015 | 10/2/2015 | 10/2/2015 | P | PASS |
Jim Little
|
|
|
would like call ahead; Bill Phone #: ###-#### >check water lines on final to be below insulation in attic
|
Groundwork | 9/17/2015 | 9/17/2015 | 9/17/2015 | P | PASS |
Jim Little
|
|
|
Bill// please call before Phone #: ###-####
|
Groundwork | 9/15/2015 | 9/15/2015 | 9/15/2015 | P | FAIL |
Jim Little
|
|
|
Bill Phone #: ###-#### >1 DWV leak at 3x2 wye for shower, cut out and replace per 310.2 upc, unlawful to conceal hole with solvent cement. >2 3" pipe at 22 does not enter hub square, redo >3" drain is backgraded at santee for wc. >4 2" shower drain needs 1/4" per ft grade >5 make repairs and retest dwv
|
Plumbing Rough-in | 9/11/2015 | 9/14/2015 | 9/14/2015 | A | FAIL |
Jim Little
|
|
|
Bill-underground Phone #: ###-#### >need proper test on dwv.
|
Issue PAID IN FULL permit | | | 9/2/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 9/2/2015 | | DONE |
|
|
|
This permit was created on the web by Bill Harmon
|