Print Statement | | | 8/30/2017 | | DONE |
|
|
|
sent 5th late notice
|
Print Statement | | | 6/15/2017 | | DONE |
|
|
|
sent 4th late notice
|
Print Statement | | | 4/20/2017 | | DONE |
|
|
|
sent 3rd late final values
|
Print Statement | | | 2/16/2017 | | DONE |
|
|
|
2nd late notice sent since 9/28/16
|
Print Statement | | | 12/23/2016 | | DONE |
|
|
|
First Letter 90 days past due
|
First Notice | 5/19/2016 | 5/19/2016 | 9/28/2016 | | DONE |
Jim Little
|
|
|
|
Print Statement | | | 9/28/2016 | | DONE |
|
|
|
|
Final | 5/19/2016 | 5/19/2016 | 5/19/2016 | P | PASS |
Jim Little
|
|
|
Juan Phone #: ###-####
|
Final | 5/18/2016 | 5/18/2016 | 5/18/2016 | P | NR |
Jim Little
|
|
|
Juan Phone #: ###-####
|
Final | 5/17/2016 | 5/17/2016 | 5/17/2016 | P | FAIL |
Jim Little
|
|
|
Juan Phone #: ###-#### >Install ASSE 1070 tempering device on lavs in bathrooms. >T&P on water heater needs a 1" airgap >open floor @ ejector pump to be able to see tank lid for inspection.
|
Plumbing Rough-in | 3/18/2016 | 3/18/2016 | 3/18/2016 | P | PASS |
Jim Little
|
|
|
Juan Phone #: ###-####
|
Plumbing Rough-in | 3/17/2016 | 3/17/2016 | 3/17/2016 | P | PART |
Jim Little
|
|
|
Juan Phone #: ###-#### >need to test ejector line >need to add nailplates
|
Groundwork | 3/1/2016 | 3/1/2016 | 3/1/2016 | P | PASS |
Jim Little
|
|
|
>G/I test ok
|
Groundwork | 2/26/2016 | 2/29/2016 | 2/29/2016 | A | PASS |
Jim Little
|
|
|
Juan Phone #: ###-#### >gw inside ok >start 24hr test on G/I
|
Groundwork | 2/26/2016 | 2/26/2016 | 2/26/2016 | P | FAIL |
Jim Little
|
|
|
Juan Phone #: ###-#### >section backgraded after new 4x3 wye installed >neeed approved band @ 4" abs to cast iron
|
Groundwork | 2/25/2016 | 2/25/2016 | 2/25/2016 | P | FAIL |
Jim Little
|
|
|
Juan Phone #: ###-#### >ejector pumps needs to tie into 4" >fix backgraded section >need 4" c/o on G/I >move 3" vent to outlet of G/I >need C/O on outlet of G/I >restest
|
Application received | | | 2/12/2016 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 2/12/2016 | | DONE |
|
|
|
|