Water Heater Final | 12/12/2016 | 12/13/2016 | 12/13/2016 | A | PASS |
Dan Ediger
|
|
|
first call
|
PLM-Aging Inspection | 12/8/2016 | 12/8/2016 | 12/12/2016 | | PEND |
Dan Ediger
|
|
|
Tagged house to call.
|
Water and/or Sewer | 5/18/2016 | 5/19/2016 | 5/19/2016 | A | FAIL |
Jim Little
|
|
|
Phone #: ###-#### Inspection requested via web by Vaughn Carlson
>608.5 ISPC—Relief valve drain piping shall not be smaller than the relief valve outlet, material used shall not reduce the internal bore of the pipe. Flex connector is not an approved material for T&P piping. >drill hole at 90 since T&P runs up hill. >drain from pan is backgraded and would allow water to sit in pan. make flat.
|
Issue PAID IN FULL permit | | | 5/18/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 5/18/2016 | | DONE |
|
|
|
This permit was created on the web by Vaughn Carlson
|