Water and/or Sewer | 12/8/2016 | 12/8/2016 | 12/8/2016 | P | PASS |
Dan Ediger
|
|
|
Fixing correction notice list please come later in pm Phone #: ###-#### Inspection requested via web by Mark Kelso
|
DOC - Permit Finaled | 12/8/2016 | 12/8/2016 | 12/8/2016 | P | PASS |
Dan Ediger
|
|
|
|
Final | 12/7/2016 | 12/8/2016 | 12/8/2016 | A | FAIL |
Dan Ediger
|
|
|
Final Inspection owner is Wong 2088908135 Phone #: ###-#### Inspection requested via web by Mark Kelso. 1. Install a tempering valve on the water heater to control the pedicure sinks. 2. Install a thermal expansion tank on the water heater. 3. Mechanically support the backflow assemblies per plans. 4. 1" RP is discharging. 5. Grade air gap lines from the backflow assemblies. 6. Provide a 1" airgap on the T&P drain. 7. Provide a tempering valve on the pedicure area hand sink. 8. Support drains on the pedicure chair drains.
|
Plumbing Rough-in | 8/29/2016 | 8/30/2016 | 8/30/2016 | P | PASS |
Daryl Spivey
|
|
|
Phone #: ###-#### Inspection requested via web by Mark Kelso
|
Groundwork | 7/21/2016 | 7/21/2016 | 7/21/2016 | P | PASS |
Jim Little
|
|
|
Phone #: ###-#### Inspection requested via web by Mark Kelso
|
Groundwork | 7/19/2016 | 7/20/2016 | 7/20/2016 | A | FAIL |
Jim Little
|
|
|
Ground work inspection sunite 140 door is unlocked no number on door but is to right of suite 150 Phone #: ###-#### Inspection requested via web by Mark Kelso >Only (3) 6 unit traps allowed on 3" horizontal dwv.
|
Issue PAID IN FULL permit | | | 7/11/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Owner Supplied Equipment | | | 7/11/2016 | | |
|
|
|
|
Application received | | | 7/11/2016 | | DONE |
|
|
|
This permit was created on the web by Mark Kelso
|
First Notice | 12/8/2016 | 12/8/2016 | | | |
Dan Ediger
|
|
|
|