PLM-Aging Inspection | 5/3/2017 | 5/3/2017 | 5/3/2017 | | PASS |
Dan Ediger
|
|
|
|
DOC - Permit Expired | 5/3/2017 | 5/3/2017 | 5/3/2017 | P | PASS |
Dan Ediger
|
|
|
finaled
|
Plumbing Rough-in | 10/25/2016 | 10/26/2016 | 10/26/2016 | A | PASS |
Eric Strole
|
|
|
8:00 AM
|
Plumbing Rough-in | 10/25/2016 | 10/25/2016 | 10/25/2016 | P | PART |
Eric Strole
|
|
|
Need to test
|
Final | 10/24/2016 | 10/25/2016 | 10/25/2016 | A | PART |
Eric Strole
|
|
|
Erica Phone #: ###-####-Cannot reduce 1 1/2 trap arm to 1 1/4.
|
Plumbing Rough-in | 10/11/2016 | 10/11/2016 | 10/11/2016 | P | PART |
Bill VanDegrift
|
|
|
Phone #: ###-#### Inspection requested via web by Erica Exline. water ok. 1. Tie 2" autowasher branch in with a wye branch. 2. Install a trap and add a vent to the bathtub. 3. Remove the "s" trap from the lavatory trap arm. 4. Put test on the waste and vent.
|
Issue PAID IN FULL permit | | | 10/11/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/11/2016 | | DONE |
|
|
|
This permit was created on the web by Erica Exline
|