Final | 5/19/2017 | 5/19/2017 | 5/19/2017 | P | PASS |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Derek Newton
|
Water and/or Sewer | 5/16/2017 | 5/16/2017 | 5/16/2017 | P | FAIL |
Dan Ediger
|
|
|
Final inspection Phone #: ###-#### Inspection requested via web by Derek Newton. Only one slip joint nut allow on the discharge side of the trap at both sinks. The dishwasher drain must loop to the bottom of the counter. The kitchen sink drain is too high to drain the garbage disposal. Remove the disposal or lower the trap arm.
|
Water and/or Sewer | 12/6/2016 | 12/7/2016 | 12/7/2016 | A | PASS |
Dan Ediger
|
|
|
2nd inspection on new kitchen plumbing to check on a correction of an undersized pipe from the sink drain to the proper diameter. Inspection requested via web by Derek Newton. Rough in ok
|
Water and/or Sewer | 12/6/2016 | 12/6/2016 | 12/6/2016 | A | PART |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Derek Newton. Kitchen sink drain required to be 2". Install 5" nail plates at all stud penitrations.
|
Issue PAID IN FULL permit | | | 11/30/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/30/2016 | | DONE |
|
|
|
This permit was created on the web by Derek Newton
|