Final | 3/23/2017 | 3/24/2017 | 3/24/2017 | A | PASS |
Bill VanDegrift
|
|
|
Phone #: ###-#### Inspection requested via web by Rob Bristol
|
Plumbing Rough-in | 12/12/2016 | 12/13/2016 | 12/13/2016 | A | PASS |
Eric Strole
|
|
|
Inspection requested via web by Rob Bristol
|
Plumbing Rough-in | 12/8/2016 | 12/12/2016 | 12/8/2016 | P | CANC |
Eric Strole
|
|
|
Phone #: ###-#### >> Inspection requested via web by Rob Bristol Inspection cancelled from web by: Rob Bristol
|
Issue PAID IN FULL permit | | | 12/8/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/8/2016 | | DONE |
|
|
|
This permit was created on the web by Rob Bristol
|