Water Heater Final | 12/14/2016 | 12/15/2016 | 12/15/2016 | A | PASS |
Dan Ediger
|
|
|
TANKLESS WATER HEATER INSTALL - THIS IS A RE-INSPECTION AFTER FAIL - CUSTOMER REQUESTS MORNING INSPECTION. PLEASE CALL WHEN EN ROUTE Phone #: ###-#### Inspection requested via web by JEREMY LINK
|
Water Heater Final | 12/12/2016 | 12/13/2016 | 12/13/2016 | A | FAIL |
Dan Ediger
|
|
|
TANKLESS WATER HEATER INSTALL CUSTOMER REQUEST MORNING INSPECTION - PLEASE CALL WHEN EN ROUTE Phone #: ###-#### Inspection requested via web by . JEREMY LINK 1. Combustion air must be taken from outside of the garage. 2. Pressure test the flue to 5psi. 3. Strap pvc pipe at max 4ft apart.
|
Issue PAID IN FULL permit | | | 12/12/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/12/2016 | | DONE |
|
|
|