Final | 5/3/2017 | 5/3/2017 | 5/3/2017 | P | PASS |
Dan Ediger
|
|
|
Call for access // Anthony Phone #: ###-####
|
Final | 4/28/2017 | 4/28/2017 | 4/28/2017 | P | FAIL |
Dan Ediger
|
|
|
Phone #: ###-####. 1. Water heater pan must be at least 2" larger that the water heater diameter with 1" clearance from the side of the pan. 2. Remove flex from the t&p and hard pipe. 3. T&p drain is trapped.
|
Final | 4/25/2017 | 4/26/2017 | 4/26/2017 | A | FAIL |
Dan Ediger
|
|
|
Anthony Phone #: ###-####. Caulk all fixtures to water tight. Gargage disposal fixting ring is not locked.
|
Plumbing Rough-in | 2/28/2017 | 3/1/2017 | 3/1/2017 | A | PASS |
Dan Ediger
|
|
|
Anthony Phone #: ###-####
|
Application received | | | 2/28/2017 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 2/28/2017 | | DONE |
|
|
|
|