Final | 1/24/2018 | 1/24/2018 | 1/24/2018 | P | PASS |
Daryl Spivey
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Final | 1/16/2018 | 1/16/2018 | 1/16/2018 | P | FAIL |
Daryl Spivey
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen need to run T&P and pan drain to approved location.........ds
|
Plumbing Rough-in | 10/31/2017 | 10/31/2017 | 10/31/2017 | P | PASS |
Daryl Spivey
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Plumbing Rough-in | 10/20/2017 | 10/23/2017 | 10/23/2017 | A | FAIL |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen. 1. The water lines are undersized on the hot and cold sides. 2. Nail plate protect all pipes with proper protection. 3. DWV pressure test failed. 4. The Master bath lav trap arm is too long. 5. Strap all water line sub-outs. 6. Install pipe insulators on the water lines going through studs. 7. Isolate all water lines from concrete.
|
Groundwork | 7/28/2017 | 7/31/2017 | 7/31/2017 | P | PASS |
Daryl Spivey
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Issue PAID IN FULL permit | | | 7/19/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/19/2017 | | DONE |
|
|
|
This permit was created on the web by Brian Johansen
|