DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice11/1/201711/1/20173/30/2018 DONE
DetailsDan Ediger
Final11/1/201711/1/201711/1/2017PPASS
DetailsDan Ediger
Final11/1/201711/1/201711/1/2017PFAIL
DetailsDan Ediger
Phone #: ###-#### Inspection requested via web by Jason Adams.
Pipe the RP air gap drain 1", full size to the outdoors. It is reduced to 1/2"
Final10/30/201710/31/201710/31/2017PFAIL
DetailsDan Ediger
Will not be available till afternoon Phone #: ###-#### Inspection requested via web by Jason Adams.
The access needs to be large enough to remove the backflow assembly without cutting the sheetrock.
Add a shut-off valve and union upstream of the backflow.
Final10/26/201710/27/201710/27/2017PFAIL
DetailsDan Ediger
Phone #: ###-#### Inspection requested via web by Jason Adams.
1. Install a tempering valve on the water heater or all public sinks.
2. The t&p on the water heater is backgrading.
3. The backflow needs to be cerified.
4. The access to the backflow must be big enough to get to the unions for removal and service.
Plumbing Rough-in8/28/20178/29/20178/29/2017APASS
DetailsDan Ediger
Brett Phone #: ###-####
Plumbing Rough-in8/25/20178/28/20178/28/2017PFAIL
DetailsDan Ediger
Fred Phone #: ###-####.
Run a 3/4" water line direct off a 1" line.
Other8/21/20178/22/20178/22/2017APASS
DetailsDan Ediger
Please call ahead to meet, questions on how to test line - Conference - Fred Phone #: ###-####.
Remove enough concrete to get a full size end of line cleanout installed and roll vent off the center line of the drain
Issue PAID IN FULL permit  8/14/2017 DONE
Payment received via Govolutions
Owner Supplied Equipment  8/14/2017  
Application received  8/14/2017 DONE