Final | 11/6/2017 | 11/6/2017 | 11/6/2017 | P | PASS |
Dan Ediger
|
|
|
early pm please call ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
|
Final | 8/23/2017 | 8/24/2017 | 8/24/2017 | A | FAIL |
Dan Ediger
|
|
|
After 9am, Thank you!! Phone #: ###-#### Inspection requested via web by Xanti Berria. The water heater drain pan is blocking the floor drain and condensation is running all over the mechanical room floor. Either remove the drain pan or drill a hole in it and run the condensate drain into the floor drain
|
Final | 8/22/2017 | 8/22/2017 | 8/22/2017 | P | FAIL |
Dan Ediger
|
|
|
late pm please call Chris ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss. The water softener drain is draining into a floor drain under the water heater without an air gap. The water softener drain must have a minimum of a 1" air gap. A stand pipe could be installed into the floor drain vent off a trap in the wall.
|
Issue PAID IN FULL permit | | | 8/22/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/22/2017 | | DONE |
|
|
|
This permit was created on the web by Xanti Berria
|