Final | 10/24/2018 | 10/24/2018 | 10/24/2018 | P | PASS |
Dan Ediger
|
|
|
Back door unlocked If not unlocked call ###-#### he can tell you where key is Phone #: ###-#### Inspection requested via web by PATTY KIRK
|
Final | 10/22/2018 | 10/23/2018 | 10/23/2018 | A | NH |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK no access. reinspection fee will be applied
|
Final | 10/16/2018 | 10/17/2018 | 10/17/2018 | A | FAIL |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK. 1. Use cpvc glue not pvc glue on cpvc pipe. 2. Address the "B" vent flue issue. 3. A disconnect or breaker lockout must be installed on the water heater power in accordance with NEC
|
Final | 7/25/2018 | 7/26/2018 | 7/26/2018 | A | FAIL |
Dan Ediger
|
|
|
Front door will be open - Contractor is Jay Bedsole if you can call he will come down there ###-#### Phone #: ###-#### Inspection requested via web by PATTY KIRK. The water heater drain pan must drain out side with grade. It isn't hooked up. The waste is pvc and trim abs. No transitions allowed. The "B" vent in the upstairs room doen't have proper clearance and is required to be framed in or protected.
|
Final | 6/27/2018 | 6/27/2018 | 6/27/2018 | A | NR |
Bill VanDegrift
|
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK lavs not set t&p seems to be ran in pvc
|
Final | 6/25/2018 | 6/27/2018 | 6/26/2018 | A | CANC |
Dan Ediger
|
|
|
Phone #: ###-#### >> Inspection requested via web by PATTY KIRK Inspection cancelled from web by: PATTY KIRK
|
Final | 6/20/2018 | 6/20/2018 | 6/20/2018 | P | NH |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK
|
Plumbing Rough-in | 3/5/2018 | 3/6/2018 | 3/6/2018 | A | PASS |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK
|
Issue PAID IN FULL permit | | | 2/14/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/14/2018 | | DONE |
|
|
|
This permit was created on the web by PATTY KIRK
|