Final | 6/8/2018 | 6/11/2018 | 6/11/2018 | A | PASS |
Eric Strole
|
|
|
Trever Phone #: ###-####
|
Plumbing Rough-in | 4/4/2018 | 4/5/2018 | 4/5/2018 | P | PASS |
Daryl Spivey
|
|
|
Trever Phone #: ###-####
|
Plumbing Rough-in | 4/2/2018 | 4/3/2018 | 4/3/2018 | A | FAIL |
Eric Strole
|
|
|
Trever Phone #: ###-####-Horizontal wet vent must include a toilet. In new construction an AAV is approved on island kitchen sinks only. Transition glue is only approved for 1 joint outside the building from the building sewer to the build drain. All base of stacks require a c/o above the floor. Need to support dwv every 4'. Need to roll wets above the invert of the drain.
|
Issue PAID IN FULL permit | | | 2/22/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/22/2018 | | DONE |
|
|
|
This permit was created on the web by Trever Currie
|