Print Statement | | | 7/22/2019 | | DONE |
|
|
|
|
Final | 2/19/2019 | 2/20/2019 | 2/20/2019 | A | PASS |
Eric Strole
|
|
|
|
Final | 2/18/2019 | 2/19/2019 | 2/19/2019 | A | PART |
Eric Strole
|
|
|
please call Kinley 30 before showing up Phone #: ###-#### Inspection requested via web by Brian Johansen-Need to run seperate water supply to soap dispensor at mop sink
|
Final | 1/30/2019 | 1/31/2019 | 1/31/2019 | A | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Temp final ok.
|
Final | 1/24/2019 | 1/24/2019 | 1/24/2019 | P | CANC |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-No TCO till approved by the city.
|
PLM-Aging Inspection | 1/24/2019 | 1/24/2019 | 1/24/2019 | | PART |
Eric Strole
|
|
|
wip
|
Plumbing Rough-in | 10/1/2018 | 10/2/2018 | 10/2/2018 | A | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Area 1A pass. Roof drains pass.
|
Plumbing Rough-in | 9/11/2018 | 9/12/2018 | 9/12/2018 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Rough-in for c-d and kitchen pass.
|
Plumbing Rough-in | 9/10/2018 | 9/11/2018 | 9/11/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Test on dwv and water area c pass. Need to nailplate and finish condensates.
|
Water and/or Sewer | 9/11/2018 | 9/12/2018 | 9/11/2018 | P | CANC |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Plumbing Rough-in | 9/5/2018 | 9/6/2018 | 9/6/2018 | A | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-DWV & water in rooms and overhead area c pass.
|
Plumbing Rough-in | 9/4/2018 | 9/5/2018 | 9/5/2018 | P | NR |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Plumbing Rough-in | 8/28/2018 | 9/4/2018 | 9/4/2018 | P | NR |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Pressure Test | 8/30/2018 | 8/30/2018 | 8/30/2018 | A | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-60 lb gas test in area D pass.
|
Roof Drains | 8/30/2018 | 8/30/2018 | 8/30/2018 | A | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Roof drains area d pass.
|
Med/Gas Systems | 8/29/2018 | 8/30/2018 | 8/30/2018 | A | CANC |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Roof Drains | 8/27/2018 | 8/28/2018 | 8/28/2018 | A | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Roof drains area c pass. Roof drains area d all but 3 roof drains pass.
|
Plumbing Rough-in | 8/27/2018 | 8/27/2018 | 8/27/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-DWV & water in area D pass. Need to use mission bands from pvc to cast iron & no-hub bands on pvc to pvc.
|
Fees Due Hold | 8/17/2018 | | 8/24/2018 | | DONE |
|
|
|
|
Roof Drains | 8/14/2018 | 8/15/2018 | 8/15/2018 | A | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Need to fix flat and backgraded primary and secondary roof drains. Need to support every 4' & nailplate.
|
Roof Drains | 8/9/2018 | 8/9/2018 | 8/9/2018 | P | DONE |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Conferance on roof drains.
|
Storm Drains | 8/8/2018 | 8/9/2018 | 8/9/2018 | P | CANC |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Roof Drains | 8/8/2018 | 8/9/2018 | 8/8/2018 | A | CANC |
Eric Strole
|
|
|
Phone #: ###-#### >> Inspection requested via web by Brian Johansen Inspection cancelled from web by: Brian Johansen
|
Groundwork | 6/14/2018 | 6/15/2018 | 6/15/2018 | A | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Water service stubbed 5' outside building pass.
|
Groundwork | 6/14/2018 | 6/14/2018 | 6/14/2018 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Groundwork | 6/12/2018 | 6/12/2018 | 6/12/2018 | A | PART |
Bill VanDegrift
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen partial gw ok
|
Groundwork | 6/6/2018 | 6/7/2018 | 6/7/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section complete is marked on plans.
|
Groundwork | 6/5/2018 | 6/6/2018 | 6/6/2018 | A | NR |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Groundwork | 6/4/2018 | 6/5/2018 | 6/5/2018 | P | NR |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Groundwork | 6/1/2018 | 6/1/2018 | 6/1/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section complete is marked on plans.
|
Groundwork | 5/29/2018 | 5/29/2018 | 5/29/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section complete is marked on plans.
|
Groundwork | 5/24/2018 | 5/24/2018 | 5/24/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section complete is marked on plans.
|
Groundwork | 5/23/2018 | 5/23/2018 | 5/23/2018 | P | NR |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Not ready
|
Groundwork | 5/17/2018 | 5/17/2018 | 5/17/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section complete is marked on plans.
|
Groundwork | 5/16/2018 | 5/16/2018 | 5/16/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section of ground work complete is marked on plans.
|
Groundwork | 5/10/2018 | 5/11/2018 | 5/11/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section complete is marked on plans.
|
Groundwork | 5/10/2018 | 5/10/2018 | 5/10/2018 | P | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Need to roll y's on vents above invert of pipe & need full size cleanouts on branch drains over 5' from building drain.
|
Groundwork | 5/8/2018 | 5/8/2018 | 5/8/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section of trunkline and groundwork complete is marked on plans.
|
Groundwork | 5/3/2018 | 5/4/2018 | 5/4/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section complete is marked on plans.
|
Groundwork | 5/3/2018 | 5/3/2018 | 5/3/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section complete is marked on plans.
|
Groundwork | 5/2/2018 | 5/2/2018 | 5/2/2018 | P | CANC |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Groundwork | 5/2/2018 | 5/2/2018 | 5/2/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section of trunkline and ground work complete is marked on plans.
|
Groundwork | 4/25/2018 | 4/25/2018 | 4/25/2018 | P | PART |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-Section of g/w complete is marked on plans.
|
Groundwork | 4/24/2018 | 4/24/2018 | 4/24/2018 | P | PART |
Eric Strole
|
|
|
Section of g/w complete is marked on plans.
|
Plumbing Rough-in | 4/24/2018 | 4/24/2018 | 4/24/2018 | P | CANC |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
Groundwork | 4/17/2018 | 4/18/2018 | 4/18/2018 | A | PART |
Eric Strole
|
|
|
Inspection requested via web by Brian Johansen-Section complete is marked on plans.
|
Groundwork | 4/13/2018 | 4/16/2018 | 4/16/2018 | A | PART |
Eric Strole
|
|
|
Deep ground Inspection requested via web by Brian Johansen-Section of trunkline complete is marked on plans.
|
Groundwork | 4/13/2018 | 4/13/2018 | 4/13/2018 | P | PART |
Eric Strole
|
|
|
Inspection requested via web by Brian Johansen-Section complete is marked on plans.
|
Groundwork | 4/13/2018 | 4/13/2018 | 4/13/2018 | A | FAIL |
Eric Strole
|
|
|
Inspection requested via web by Brian Johansen-Need to fix backgraded drains.
|
Groundwork | 4/12/2018 | 4/12/2018 | 4/12/2018 | A | PART |
Eric Strole
|
|
|
Section of g/w complete is marked on plans
|
Groundwork | 4/11/2018 | 4/12/2018 | 4/12/2018 | A | CANC |
Eric Strole
|
|
|
Inspection requested via web by Brian Johansen
|
Storm Drains | 4/11/2018 | 4/11/2018 | 4/11/2018 | P | PART |
Eric Strole
|
|
|
Storm drain through building Inspection requested via web by Brian Johansen-Section of roof drain underslab inspected is marked on plans.
|
Groundwork | 4/4/2018 | 4/5/2018 | 4/5/2018 | A | PART |
Daryl Spivey
|
|
|
Storm drain through building Inspection requested via web by Brian Johansen sleeves only
|
Groundwork | 4/4/2018 | 4/4/2018 | 4/4/2018 | P | PART |
Eric Strole
|
|
|
Deep ground Inspection requested via web by Brian Johansen-Section of trunkline tested and passed is marked on plans
|
Groundwork | 4/3/2018 | 4/3/2018 | 4/3/2018 | P | FAIL |
Eric Strole
|
|
|
Deep ground Inspection requested via web by Brian Johansen-DWV test fail.
|
Groundwork | 4/2/2018 | 4/2/2018 | 4/2/2018 | P | PART |
Eric Strole
|
|
|
Deep ground Inspection requested via web by Brian Johansen-Section of trunkline tested and complete is marked on plans.
|
Groundwork | 3/30/2018 | 4/2/2018 | 4/2/2018 | A | FAIL |
Eric Strole
|
|
|
Deep ground Inspection requested via web by Brian Johansen-DWV test fail
|
Groundwork | 3/27/2018 | 3/28/2018 | 3/28/2018 | A | FAIL |
Eric Strole
|
|
|
Inspection requested via web by Brian Johansen-Need to plumb per the approved plans or resubmit plans.
|
Issue PAID IN FULL permit | | | 3/26/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/26/2018 | | DONE |
|
|
|
This permit was created on the web by Brian Johansen
|
First Notice | 2/20/2019 | 2/20/2019 | | | |
Eric Strole
|
|
|
|