Final | 4/4/2019 | 4/4/2019 | 4/4/2019 | P | PASS |
Eric Strole
|
|
|
Lock box code is 1830 Phone #: ###-#### Inspection requested via web by Steve Spence
|
Final | 4/3/2019 | 4/4/2019 | 4/4/2019 | A | FAIL |
Eric Strole
|
|
|
Lock box code is 1830 Phone #: ###-#### Inspection requested via web by Steve Spence-Need to caulk all toilets and tub/shower trim.
|
Final | 3/28/2019 | 3/29/2019 | 3/29/2019 | A | FAIL |
Dan Ediger
|
|
|
1. Kitchen: ISPC 419.2 Dishwasher cannot tie into a tailpiece downstream of the disposal. 2. Pool Bath: No water pressure at lav. Shower strainer defective 3. Fire: Certify double check and add to permit. 3. East water heater: The condesate from the fau cannot block the water heater. The line set must be installed prior to final to ensure it doesn't encomber the water heater. Caulk all water closets and shower trims.
|
Final | 3/28/2019 | 3/28/2019 | 3/28/2019 | A | CANC |
Dan Ediger
|
|
|
code is 1830 Phone #: ###-#### Inspection requested via web by Steve Spence
|
Final | 3/27/2019 | 3/28/2019 | 3/28/2019 | A | CANC |
Eric Strole
|
|
|
code is 4657 Phone #: ###-#### >> Inspection requested via web by Steve Spence Inspection cancelled from web by: Steve Spence
|
Other | 3/12/2019 | 3/12/2019 | 3/13/2019 | P | PASS |
Dan Ediger
|
|
|
1:30 PM Went over roof drain scupper requirements and testing witht the plumbing and builder
|
Other | 3/13/2019 | 3/13/2019 | 3/13/2019 | P | PART |
Eric Strole
|
|
|
1:30 Conference-Conferance on roof drains. They will pull a seperate permit for roof drains and get calculations for roof drain sizing over to plan review.
|
Other | 2/21/2019 | 2/21/2019 | 2/21/2019 | A | FAIL |
Eric Strole
|
|
|
Left correction notice. 1-Roof drains need to be installed by a plumbing contractor. 2-Roof drains require overflow drains or scuppers. 3-Roof drains are required to be tested. 4-Need specs on roof drains that are installed.5-Need to size roof drains per the 2017 ISPC.
|
Plumbing Rough-in | 2/20/2019 | 2/20/2019 | 2/20/2019 | P | CANC |
Eric Strole
|
|
|
Inspect 2 toilets hooked up to the Fire Sprinkler Lines. One in master and one upstairs bath. Phone #: ###-#### Inspection requested via web by Steve Spence
|
Plumbing Rough-in | 7/20/2018 | 7/24/2018 | 7/24/2018 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Steve Spence
|
Groundwork | 4/25/2018 | 4/25/2018 | 4/25/2018 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Steve Spence
|
Issue PAID IN FULL permit | | | 4/25/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 4/25/2018 | | DONE |
|
|
|
This permit was created on the web by Steve Spence
|