Final | 7/3/2018 | 7/3/2018 | 7/3/2018 | P | PASS |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Gonzalez
|
Plumbing Rough-in | 5/2/2018 | 5/3/2018 | 5/3/2018 | P | PASS |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Gonzalez
|
Plumbing Rough-in | 4/30/2018 | 5/1/2018 | 5/1/2018 | P | FAIL |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Gonzalez. 1. defective water gauge. 2. Failed dwv test. 3. Cannot use oil based putty on abs. 4. 3" drop is backgrading at the wye branch in the wall.. 5. Missing nail plate at the kitchen sink.
|
Issue PAID IN FULL permit | | | 4/25/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 4/25/2018 | | DONE |
|
|
|
This permit was created on the web by Jason Gonzalez
|