Water Heater Final | 2/27/2019 | 3/4/2019 | 3/4/2019 | A | PASS |
Matt Wrobel
|
|
|
Please call Julia when in route ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Jennifer Alcala
|
Final | 2/27/2019 | 2/27/2019 | 2/27/2019 | P | FAIL |
Matt Wrobel
|
|
|
Julia Phone #: ###-#### t&p Still has a flex connector which is not allowed need to run in approved materials.
|
Water Heater Final | 7/5/2018 | 7/9/2018 | 7/9/2018 | P | FAIL |
Dan Ediger
|
|
|
If you can contact homeowner Julia when 30 mins in route at ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Jennifer Alcala. 1. Pipe the pan drain to the outside of the house. 2. The t&p must be hard piped. 3. An electrical disconnect must be installed at the heater or a lockout at the breaker. 4. Make a proper electrical connection to the water heater.
|
Issue PAID IN FULL permit | | | 7/2/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/2/2018 | | DONE |
|
|
|
This permit was created on the web by Jennifer Alcala
|