Final | 9/19/2019 | 9/20/2019 | 9/20/2019 | A | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Jeffrey Hankins
|
Final | 9/15/2019 | 9/16/2019 | 9/16/2019 | A | PART |
Eric Strole
|
|
|
master bath vanities and grout are not completed. can i get a partial inspecrion to allow builder to finalize the loan process? Phone #: ###-#### Inspection requested via web by Jeffrey Hankins-Master bath not complete. Part final ok.
|
Plumbing Rough-in | 6/17/2019 | 6/18/2019 | 6/18/2019 | A | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Jeffrey Hankins
|
Plumbing Rough-in | 6/16/2019 | 6/17/2019 | 6/17/2019 | A | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Jeffrey Hankins-PVC require a purple primer or an approved one step glue. Missing nailplates.
|
Plumbing Rough-in | 6/13/2019 | 6/14/2019 | 6/14/2019 | A | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Jeffrey Hankins-Need to fix backgrade on toilet trap-arm in crawl. 1 1/2 santee on vent in master bath installed incorrect. Missing nailplates.
|
Issue PAID IN FULL permit | | | 6/13/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/13/2019 | | DONE |
|
|
|
This permit was created on the web by Jeffrey Hankins
|