Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberPLM19-04887
StatusFinaled
Name DALTON HEIDI L FAMILY TRUST 8/31/16
Site Address 5800 N GARY LN
Project NameRodgers Remodel
Customer Number 
ePlanReviewNo
Description
Repipe water and waster lines to new kitchen, laundry and bath fixtures. (1 kitchen sink, 2 other sinks, diswasher and garbage disposal)
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/3/20203/4/20203/4/2020APASS
DetailsDaryl Spivey
Shea Phone #: ###-####
Plumbing Rough-in12/19/201912/20/201912/20/2019APASS
DetailsDaryl Spivey
Shea Phone #: ###-####
Plumbing Rough-in12/18/201912/19/201912/19/2019PPART
DetailsDaryl Spivey
Shea Phone #: ###-####
change venting on kit.........ds
Plumbing Rough-in12/13/201912/16/201912/16/2019AFAIL
DetailsEric Strole
Shea Phone #: ###-####-San tees are only approved for drainage in the vertical. Need to equal cross sectional venting. Need to nailplate. Need to test dwv & water. Need to add c/o at kitchen. Y installed backwards backwards on 2" drain downstream of kitchen.
Application received  11/13/2019  
Issue PAID IN FULL permit  11/13/2019 DONE