Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberPLM20-01423
StatusIssued
Name ASAP INC
Site Address 12560 W FREEDOM DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Sewer Service ONLY: Converting septic tank in back yard to a lifting station. Pressurizing the effluent through a 2 inch line and connecting it to the city sewer stub on West Freedom Drive.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Water and/or Sewer4/9/20204/10/20204/10/2020APASS
DetailsMatt Wrobel
Added 4 clean outs to the 2 inch pressure line. Clean outs were placed at every 50 feet. Thank you Isaac ASAP Septic. Phone #: ###-#### Inspection requested via web by Isaac Gordon
Water and/or Sewer4/9/20204/9/20204/9/2020PPART
DetailsMatt Wrobel
screened call for access // Isaac // pressure gauge in back yard in lifting station. Phone #: ###-####
need to add cleanouts every 50 feet in 2 inch line need cleanout at tank can be in cover of riser. NEED TO ADD CLEANOUTS AND SHOW BEFORE COVER.
Issue PAID IN FULL permit  3/31/2020 DONE
Payment received via Govolutions
Application received  3/31/2020 DONE
This permit was created on the web by Isaac Gordon