Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberPLM20-02583
StatusIssued
Name H&L CONSTRUCTION LLC
Site Address 6120 E BARBER DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Plumbing Installation: Rough in
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Plumbing Rough-in7/7/20207/8/20207/8/2020APASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Lance Manning
Plumbing Rough-in7/5/20207/6/20207/6/2020AFAIL
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Lance Manning-Dwv test fail & vent to close to opening window.
Plumbing Rough-in6/25/20206/26/20206/25/2020ACANC
DetailsEric Strole
contact is Lance Phone #: ###-#### >> Inspection requested via web by Lance Manning Inspection cancelled from web by: Lance Manning
Plumbing Rough-in6/25/20206/25/20206/25/2020PFAIL
DetailsDan Ediger
Phone #: ###-#### Inspection requested via web by Lance Manning
1. DWV test failed.
2. Strap DWV at 4ft and end of line/trap arms.
3. Grade all waste at 1/4 ft.
4. Install full size cleanouts w/in 5ft of crawl or above floor.
Issue PAID IN FULL permit  6/23/2020 DONE
Payment received via Govolutions
Application received  6/23/2020 DONE
This permit was created on the web by Lance Manning