BLD-Final | 8/9/2001 | 8/10/2001 | 8/10/2001 | P | PASS |
Tony Young
|
|
|
fn insp phil ###-####
|
BLD-Grading Inspection | 8/9/2001 | 8/9/2001 | 8/9/2001 | | BOND |
Rita DeYoung
|
|
|
Final grading has been completed according to the approved plan. Revegetation has not been completed and for this the engineer has recommended a $500.00 bond. Upon receipt of this bond the grading is conditionally approved.
|
FIRE-Final Inspection | 7/25/2001 | 7/26/2001 | 7/26/2001 | A | PASS |
Rick Jackson
|
|
|
###-####
|
BLD-Concrete | 4/2/2001 | 4/2/2001 | 4/2/2001 | P | PART |
Tony Young
|
|
|
###-####
bond beam in fireplace 4/2/2001 2:23:19 PM
|
BLD-Concrete | 3/22/2001 | 3/23/2001 | 3/23/2001 | P | PART |
Tony Young
|
|
|
###-####
bond beam on chimney, ok to grout 3/23/2001 12:59:12 PM
|
BLD-Concrete | 3/16/2001 | 3/19/2001 | 3/19/2001 | A | PART |
Tony Young
|
|
|
bond beam ok on fireplace 3/19/2001 12:14:44 PM
|
BLD-Concrete | 3/16/2001 | 3/16/2001 | 3/16/2001 | P | PART |
Tony Young
|
|
|
###-####
wip, masonary chimney 3/16/2001 1:36:24 PM
|
BLD-Framing/Rough-in | 3/15/2001 | 3/15/2001 | 3/15/2001 | P | PASS |
Tony Young
|
|
|
###-####
fire place slab ok and int. drywall shear ok 3/15/2001 4:11:18 PM
|
BLD-Framing/Rough-in | 3/8/2001 | 3/9/2001 | 3/9/2001 | A | PART |
Tony Young
|
|
|
###-####
c/n still pending, insulation ok, ok to sheet rock unaffected areas 3/9/2001 11:24:31 AM
|
FIRE-Sprinkler Rough-in | 3/6/2001 | 3/7/2001 | 3/7/2001 | A | PASS |
Rick Jackson
|
|
|
###-#### okay to cover 3/7/2001 10:21:24 AM
|
BLD-Framing/Rough-in | 3/5/2001 | 3/6/2001 | 3/6/2001 | A | FAIL |
Tony Young
|
|
|
Phil ###-####
c/n posted, need fire sprinklers signed off, ok to insulate after trades sign off 3/6/2001 1:19:40 PM
|
BLD-Framing/Rough-in | 2/8/2001 | 2/9/2001 | 2/9/2001 | A | PART |
Tony Young
|
|
|
###-####
exterior shear ok, working on some, need to see interior shear later 2/9/2001 12:53:22 PM
|
BLD-Foundation | 11/13/2000 | 11/13/2000 | 11/13/2000 | P | PART |
Tony Young
|
|
|
FOUND WALL --DOONIE ###-####
wip, ok w/ verbal corrections 11/13/2000 12:42:13 PM
|
BLD-Foundation | 11/3/2000 | 11/6/2000 | 11/6/2000 | A | PART |
Tony Young
|
|
|
found wall- donnie ###-####
work in progress, ok w/ verbal corrections 11/6/2000 11:58:49 AM
|
BLD-Footing | 10/25/2000 | 10/26/2000 | 10/26/2000 | A | PART |
Tony Young
|
|
|
###-####
wip, ok w/ verbal corrections 10/26/2000 9:52:34 AM
|
BLD-Foundation | 10/2/2000 | 10/2/2000 | 10/2/2000 | P | PART |
Tony Young
|
|
|
donny ###-#### foundation wall
|
BLD-Footing | 9/13/2000 | 9/14/2000 | 9/14/2000 | A | FAIL |
Tony Young
|
|
|
ft insp-- donny ###-####
need soil rpt. 9/14/2000 12:30:28 PM
|
BLD-Footing | 9/14/2000 | 9/14/2000 | 9/14/2000 | P | NR |
Tony Young
|
|
|
donny ###-####
|
BLD-Footing | 9/14/2000 | 9/14/2000 | 9/14/2000 | P | PART |
Tony Young
|
|
|
Scheduled by Inspector: 415 On 9/14/2000
part on basement ftgs 9/14/2000 3:16:17 PM
|
BLD-Framing/Rough-in | 3/2/2001 | 3/5/2001 | 3/6/2000 | P | FAIL |
Russ Owen
|
|
|
###-####c/n posted. 3/6/2001 1:03:55 PM
|