BLD-Final | 3/1/2002 | 3/4/2002 | 3/4/2002 | A | PASS |
Jim Storey
|
|
|
Scheduled by Inspector: 407 On 3/1/2002 11:26:04 AM final ok for c.o. 3/4/2002 2:52:12 PM
|
Permanent Occupancy | | 3/4/2002 | 3/4/2002 | | DONE |
|
|
|
|
BLD-Final | 2/28/2002 | 3/1/2002 | 3/1/2002 | A | CANC |
Russ Owen
|
|
|
###-#### John ,I called left message to call me back I have set this back up for am monday.1/2002 11:51:03 AM 3/1/2002 11:54:03 AM
|
BLD-Final | 2/20/2002 | 2/21/2002 | 2/21/2002 | A | FAIL |
Jim Storey
|
|
|
###-#### DON fire stopping needed at plm. 2/21/2002 9:20:13 AM
|
BLD-Final | 1/31/2002 | 2/1/2002 | 2/1/2002 | P | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 01/31/2002 at 08:04:18. Contact: ###-####. recieved engineers approval letter and special insp approval. ok for temp. 2/1/2002 2:41:28 PM
|
FIRE-Final Inspection | 1/31/2002 | 2/1/2002 | 2/1/2002 | A | PASS |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 01/31/2002 at 08:03:29. Contact: ###-####.
|
FIRE-Final Inspection | 1/17/2002 | 1/17/2002 | 1/17/2002 | A | FAIL |
Rick Jackson
|
|
|
Added by Inspector: 409 On 1/17/2002 11:01:35 AM need exit signs on second floor; sprinkler certification paperwork; tested alarms - okay with monor corections
|
BLD-Conference | 11/15/2001 | 11/16/2001 | 11/16/2001 | A | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 11/15/2001 at 10:55:35. Contact: ###-####. fire shudder test req/ fire stop top of corridor walls south east exit. pending all other trades. need engineers sign off and special insp. final letter. 11/16/2001 11:02:24 AM
|
BLD-Conference | 11/15/2001 | 11/19/2001 | 11/15/2001 | A | CANC |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 11/15/2001 at 10:34:15. Contact: . Disp set to [CANC] by a contractor via Hello! on 11/15/2001 at 10:54:16.
|
BLD-Final | 10/30/2001 | 11/5/2001 | 11/1/2001 | A | CANC |
Jim Storey
|
|
|
###-#### Disp set to [CANC] by a contractor via Hello! on 11/01/2001 at 14:37:43.
|
FIRE-Final Inspection | 10/29/2001 | 11/1/2001 | 11/1/2001 | A | NR |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 10/29/2001 at 14:46:09. Contact: ###-####. will reschedule 10/31/2001 5:07:37 PM
|
BLD-Conference | 10/18/2001 | 10/19/2001 | 10/19/2001 | A | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 10/18/2001 at 14:46:29. Contact: ###-####.
|
BLD-Other | 9/17/2001 | 9/18/2001 | 9/18/2001 | P | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 09/17/2001 at 12:59:16. Contact: ###-####. 2 nd floor ceilling/ need speader bars. 9/18/2001 10:40:59 AM
|
BLD-Other | 9/5/2001 | 9/7/2001 | 9/7/2001 | A | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 09/05/2001 at 15:22:43. Contact: ###-####. south 1/2 ceilling ok. 9/10/2001 5:54:47 PM
|
BLD-Framing/Rough-in | 8/8/2001 | 8/9/2001 | 8/9/2001 | A | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 08/08/2001 at 09:42:32. Contact: ###-####. hard ceilling at west dock beams protccted and support grid ok for cover/ grid ceilling 2 nd floor work in progess no problems. 8/9/2001 11:39:12 AM
|
BLD-Framing/Rough-in | 7/9/2001 | 7/10/2001 | 7/10/2001 | A | PASS |
Jim Storey
|
|
|
Jualo ###-####
|
BLD-Framing/Rough-in | 5/16/2001 | 5/17/2001 | 5/17/2001 | A | PASS |
Jim Storey
|
|
|
Hulo ###-#### 1 & 2nd floor framing ok for cover / arch to address west stair for opening protection. 5/17/2001 9:50:16 AM
|
BLD-Framing/Rough-in | 5/10/2001 | 5/14/2001 | 5/14/2001 | A | PASS |
Jim Storey
|
|
|
###-#### 2nd floor ok for cover. 5/14/2001 4:34:15 PM
|
BLD-Framing/Rough-in | 5/3/2001 | 5/8/2001 | 5/8/2001 | A | FAIL |
Jim Storey
|
|
|
Jullo ###-#### c/n for rfi to arch. 5/8/2001 1:03:24 PM
|
BLD-Framing/Rough-in | 5/1/2001 | 5/3/2001 | 5/3/2001 | A | PART |
Steven Webb
|
|
|
julio-- ###-#### fr Partial--Building 35-2nd floor offices at east and west end. 5/3/2001 9:55:27 AM
|
BLD-Framing/Rough-in | 4/16/2001 | 4/16/2001 | 4/16/2001 | P | PART |
Jim Storey
|
|
|
###-#### fur out walls ok for cover / c/n for out standing special insp. issues. 4/16/2001 6:31:30 PM
|
BLD-Framing/Rough-in | 3/14/2001 | 3/15/2001 | 3/15/2001 | A | PART |
Jim Storey
|
|
|
###-#### diaphram roof welds ok south end. reviewed col/fire assemblie/ 3/15/2001 4:37:51 PM
|
BLD-Framing/Rough-in | 3/12/2001 | 3/13/2001 | 3/13/2001 | A | FAIL |
Jim Storey
|
|
|
WELDING ON ROOF AND FLOOR DECKING\\###-#### missing welds and botton punching on roof and 2 nd floor / special insp need to verify when corected. 3/13/2001 10:18:49 AM
|
BLD-Other | 2/28/2001 | 2/28/2001 | 2/28/2001 | | FAIL |
Jim Storey
|
|
|
special insp report feb 16 2001. tilt panels 14,15,16,20,22,23 air spec. 4% to 7% test results were 2% need engineer of record to justify not meetting freeze protection provision and design spec.
|
BLD-Foundation | 1/18/2001 | 1/18/2001 | 1/18/2001 | P | PART |
Jim Storey
|
|
|
re-bar julio ###-#### placed with special insp. pending report. 1/18/2001 4:14:29 PM
|
BLD-Framing/Rough-in | 1/4/2001 | 1/5/2001 | 1/5/2001 | P | PART |
Jim Storey
|
|
|
REBAR JULIO-- ###-#### placed with special insp. pending report. 1/8/2001 7:57:48 AM
|
BLD-Other | 12/29/2000 | 12/29/2000 | 12/29/2000 | A | FAIL |
Bill VanDegrift
|
|
|
Added by Inspector: 330 On 12/29/2000 3:57:54 PM left correction notice - secure a permit for sewer and water lines relocated outside the building, provide documentation from micron reguarding testing and inspection for determination of code compliance, - secure a licensed plumbing contractor to permit 10" storm drain under the building apply test and call for inspection- do not lay asphalt over exterior piping or concrete over interior storm drain untill all waor has been approved for cover.
|
BLD-Footing | 12/21/2000 | 12/22/2000 | 12/22/2000 | A | PART |
Carl Dependahl
|
|
|
Garry ###-####; pend spec. insp reports 12/22/2000 10:14:24 AM
|
BLD-Footing | 12/14/2000 | 12/15/2000 | 12/15/2000 | A | NR |
Jim Storey
|
|
|
###-####
|
BLD-Foundation | 12/13/2000 | 12/13/2000 | 12/13/2000 | P | PART |
Jim Storey
|
|
|
###-#### REBAR placed with special insp. 12/13/2000 4:43:04 PM
|
BLD-Foundation | 12/5/2000 | 12/5/2000 | 12/5/2000 | P | PART |
Jim Storey
|
|
|
###-#### work in progess covered with s/i 12/5/2000 3:34:36 PM
|
BLD-Footing | 11/27/2000 | 11/28/2000 | 11/28/2000 | P | PART |
Jim Storey
|
|
|
###-#### p/w/s/i/ pending report. 11/28/2000 3:49:21 PM
|
FIRE-Final Inspection | 11/27/2000 | 11/28/2000 | 11/28/2000 | P | CANC |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 11/27/2000 at 14:55:29. Contact: ###-####.//// entered by contractor in error 11/28/2000 3:22:58 PM
|