Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberBLD00-02434
StatusFinaled
Name UDELL WILLIAM TRUST AND
Site Address 9176 W FAIRVIEW AVE
Project NameIMAGE AUTO SALES
Customer Number 
ePlanReviewNo
Description
IMAGE AUTO SALES * TO CONSTRUCT A 2300 SQ. FT. ONE STORY, TYPE VN, FULLY FIRE SPRINKLERED CAR SALES WITH PARKING\WASHBAY GARAGE. OFFICE\SALES AREA IS 1500 SQ. FT. WITH THE GARAGE AREA AT 800 SQ. FT. NO OPENINGS ARE INCLUDED BETWEEN THE GARAGE AND OFFICE PER THIS PERMIT. DRH00-00173 PC#665-00 GRADING PERMIT BLD00-02464 FIRE SPRINKLERS CAN BE USED FOR AREA INCREASE.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Other8/17/20018/17/20018/17/2001PDONE
DetailsBob Archibald
Bond has been posted - ok to sign off for final
Permanent Occupancy 8/17/20018/17/2001 DONE
Details
BLD-Conference8/9/20018/9/20018/9/2001PDONE
DetailsDave Hannah
Leave CN requirering posting of bond with Public works for issuance of certificate of occupancy. 8/10/2001 3:28:49 PM owner is allready working with bill shoud have bond some time next week 8/10/2001 3:29:52 PM
BLD-Aging Inspection7/9/20017/9/20017/9/2001 PASS
DetailsDave Hannah
BLD-Final5/7/20015/8/20015/8/2001APASS
DetailsDave Hannah
Final - reinspect
BLD-Final3/30/20014/3/20014/3/2001ACANC
DetailsDave Hannah
Bill, ###-####
BLD-Final4/2/20014/3/20014/3/2001ANR
DetailsDave Hannah
###-#### 4/3/2001 4:26:31 PM
BLD-Final3/29/20013/30/20013/30/2001PFAIL
DetailsDave Hannah
###-#### 3/30/2001 2:33:59 PM NEED TO FIRE CALLOR PLUMBING VENTS AND BOTTOM OF WALL IN ATTIC 3/30/2001 2:35:37 PM
FIRE-Final Inspection3/29/20013/30/20013/30/2001APASS
DetailsJoe Tawney
###-#### Reinsp OK for permanant occupancy 3/30/2001 12:43:03 PM
FIRE-Final Inspection3/13/20013/14/20013/14/2001AFAIL
DetailsJoe Tawney
fire fn bill ###-#### Reinsp Fail C/N not done 3/14/2001 12:30:43 PM
FIRE-Final Inspection3/5/20013/6/20013/6/2001AFAIL
DetailsJoe Tawney
Bill, ###-#### Reinsp Fail C/N issued 3/6/2001 12:38:34 PM
FIRE-Final Inspection3/1/20013/1/20013/1/2001PFAIL
DetailsJoe Tawney
###-#### Final Fail C/N issued 3/2/2001 8:17:05 AM
BLD-Other1/16/20011/17/20011/17/2001PPASS
DetailsDave Hannah
Scheduled by a contractor via Hello! on 01/16/2001 at 18:03:23. Contact: ###-####.insulation and seal kit ok tocover 1/17/2001 1:06:23 PM
BLD-Framing/Rough-in1/15/20011/16/20011/16/2001PPASS
DetailsDave Hannah
Scheduled by a contractor via Hello! on 01/15/2001 at 15:24:11. Contact: ###-####.
BLD-Framing/Rough-in1/10/20011/11/20011/11/2001AFAIL
DetailsDave Hannah
brent ###-#### fr not ready they didnt have
mec elec rough ins 1/11/2001 11:53:45 AM
BLD-Framing/Rough-in12/18/200012/19/200012/19/2000APART
DetailsDave Hannah
Bill ###-#### shear nailing ok to cover north west& south walls east wall has three staps that are wrong need eng fix ok to cover if fix is on inside of wall

12/19/2000 11:04:11 AM

12/19/2000 11:05:55 AM
BLD-Conference12/12/200012/13/200012/13/2000PPART
DetailsTom Arcoraci
CONF-- BILL-- ###-#### 12/13/2000 2:33:48 PM may have eng design cut for trusss at one hour wall 12/13/2000 5:16:15 PM
BLD-Conference12/8/200012/8/200012/8/2000PPASS
DetailsDave Hannah
BRENT ###-#### FOR CONF 12/8/2000 2:02:03 PM
BLD-Conference12/4/200012/5/200012/5/2000AFAIL
DetailsTom Arcoraci
FOR CONF-- BRENT ###-#### 12/5/2000 9:15:19 AM occ sep not per plan 12/5/2000 11:11:30 AM
BLD-Footing11/3/200011/6/200011/6/2000APASS
DetailsDave Hannah
###-#### brent