Permit Information
Permit NumberBLD00-02871
StatusFinaled
Name LINEN BARN
Site Address 6910 S EISENMAN RD
Project NameFACTORY OUTLET MALL
Customer Number 
ePlanReviewNo
Description
*LINEN BARN - NEW TENANT* To remove interior NB walls and existing tenant separation wall between two existing spaces, 6910 & 6914 Eisenman Road to become one 6,451 sq. ft. retail tenant space per approved plans on file. Work to include removal of 80 lineal ft. of 1-hr. tenant demising wall and construction of new interior partitions to create hallways to rear exists, one office and a small stock room. NOTE: This building is fully fire sprinklered for area increase. (P.C.#789-00)/drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection4/30/20014/30/20014/30/2001PCANC
DetailsJoe Tawney
phil ###-#### fire fn Cancel History shows permit signed off. Contr will call Rick to verify 4/30/2001 4:43:19 PM
Permanent Occupancy 2/7/20012/7/2001 DONE
Details
BLD-Final2/5/20012/6/20012/6/2001PPASS
DetailsJim Storey
I have the occ. card - all others have signed off.
FIRE-Final Inspection2/5/20012/5/20012/5/2001PPASS
DetailsRick Jackson
Scheduled by Inspector: 409 On 2/5/2001 1:39:46 PM fire alarm duct detectors complete per FIR00-00677 2/5/2001 1:40:32 PM
FIRE-Final Inspection12/8/200012/8/200012/8/2000APART
DetailsRick Jackson
Added by Inspector: 409 On 12/8/2000 11:12:53 AM awaiting plans for the duct detectors
BLD-Final12/6/200012/7/200012/7/2000APART
DetailsJim Storey
FN OCC ###-#### -PHIL ok pending fire signoff. 12/7/2000 10:52:24 AM
FIRE-Final Inspection12/6/200012/7/200012/7/2000AFAIL
DetailsRick Jackson
PHIL ###-#### FIRE FN /// need to hang extinguisher in stockroom; replace painted sprinkler heads; duct detectors aren't tied into the fire alarm panel 12/7/2000 10:09:22 AM
BLD-Framing/Rough-in11/16/200011/17/200011/17/2000APASS
DetailsJim Storey
Phil ###-#### need racking info. for lateral design zone 2b/screws in top leg of ceilling rafter n/w storeroom./duct dector for hvac uints if total is over 2000 cfm. 11/17/2000 10:53:47 AM