Permit Number | BLD00-02910 |
Status | Finaled |
Name |
VACANT (COUNTRY SQUARE SHOPPING CNTR)
|
Site Address |
10533 W OVERLAND RD
|
Project Name | COUNTRY SQUARE SHOPPING CENTER |
Customer Number | |
ePlanReview | No |
Description |
To upgrade to a 2-hr. rated area separation wall to full code compliance and other miscellaneous work in vacant tenant space of an existing shopping center per approved plans on file. The area separation wall is on the west side of this tenant space. This work will bring the allowable area of the shopping center into code compliance. The shopping center was recently annexed into Boise City. Work to include extending area separation parapet wall above roof 30" minimum and extending the wall horizontally to outer edge of existing roof projection, masonry work, epoxy/adhesive anchor installations, new concrete footing under masonry wall extension, two-hour rated interior infill wall in existing overhead door opening in area separation wall, new (3) coat exterior stucco work, upgrading existing draft stops in tenant space to code compliance, some fire sprinkler modifications including alleviating sagging roof insulation so sprinkler heads will not be obstructed, and some electrical work. NOTE: Work requires Special Inspections. NO OCCUPANCY allowed under this permit. A separate permit is required to occupy the space. This is a Scope of Work Permit. Letter of Completion to be issued when done. NOTE: This building has a fire sprinkler system for area increase and the system will require upgrades under separate permits. (P.C.#803-00) JCB
|