BLD-Final | 5/2/2001 | 5/3/2001 | 5/3/2001 | P | PASS |
Steven Webb
|
|
|
###-#### 0474 send is the code C. of C. #21441 issued. 5/3/2001 1:20:27 PM
|
BLD-Energy code compliance | 2/8/2001 | 2/9/2001 | 2/9/2001 | A | PASS |
Tom Arcoraci
|
|
|
Nick ###-####
|
BLD-Framing/Rough-in | 2/6/2001 | 2/7/2001 | 2/7/2001 | A | PART |
Steven Webb
|
|
|
Nick ###-####c/n issued---ok to insulate 2/7/2001 12:49:23 PM
|
BLD-Framing/Rough-in | 1/29/2001 | 1/29/2001 | 1/29/2001 | P | PASS |
Steven Webb
|
|
|
shear wall bob-- ###-#### ok to side 1/29/2001 2:12:15 PM
|
BLD-Framing/Rough-in | 1/24/2001 | 1/25/2001 | 1/25/2001 | A | FAIL |
Steven Webb
|
|
|
SHEAR WALL -NICK ###-#### c/n issued, 1) Hd missing corner of moring room, 2) renail shear panels in compliance of shear plan, 3) Blocks needed at plywood joints on shear panels at various locations, 4) instal MSTC 40 straps per plans on upstair bedroom 4 per plans, 5) Nailing needed above hd straps 1/25/2001 12:00:18 PM
|
BLD-Foundation | 12/15/2000 | 12/18/2000 | 12/18/2000 | A | PASS |
Steven Webb
|
|
|
FOUND BRENT ###-####: 12/18/2000 8:02:17 AM Added on 12/15/2000 by phone request. 12/18/2000 8:02:57 AM
|
BLD-Foundation | 12/15/2000 | 12/15/2000 | 12/15/2000 | P | PART |
Steven Webb
|
|
|
Added by Inspector: 420 On 12/15/2000 2:48:48 PM Early Start permit, no approved plans on site.
|
BLD-Footing | 12/13/2000 | 12/14/2000 | 12/14/2000 | A | PART |
Steven Webb
|
|
|
late am please Brent ###-####Early Start, appears ok. 12/14/2000 11:03:16 AM
|