FIRE-Final Inspection | 7/19/2001 | 7/19/2001 | 7/19/2001 | A | PASS |
Rick Jackson
|
|
|
Added by Inspector: 409 On 7/19/2001 8:04:12 AM
|
Permanent Occupancy | | 7/19/2001 | 7/19/2001 | | DONE |
|
|
|
|
BLD-Final | 7/17/2001 | 7/18/2001 | 7/18/2001 | A | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 07/17/2001 at 08:41:24. Contact: ###-####. final ok pending fire sign off. 7/18/2001 5:04:48 PM
|
BLD-Final | 7/17/2001 | 7/18/2001 | 7/18/2001 | A | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 07/17/2001 at 08:41:24. Contact: ###-####. final ok pending fire sign off. 7/18/2001 5:04:48 PM
|
FIRE-Alarm Testing | 7/17/2001 | 7/18/2001 | 7/18/2001 | A | FAIL |
Rick Jackson
|
|
|
BUCK ###-#### FIRE ALM TEST c/n issued 7/18/2001 9:41:54 AM
|
FIRE-Final Inspection | 7/17/2001 | 7/18/2001 | 7/18/2001 | A | FAIL |
Rick Jackson
|
|
|
AT 8:30 ??? BUCK-- ###-#### FN FIRE
|
FIRE-Alarm Testing | 7/16/2001 | 7/17/2001 | 7/17/2001 | P | CANC |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 07/16/2001 at 11:11:36. Contact: ###-####. CANCEL PER BUCK
|
FIRE-Final Inspection | 7/16/2001 | 7/17/2001 | 7/17/2001 | P | CANC |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 07/16/2001 at 11:12:47. Contact: ###-####.--CANCEL PER BUCK/MLS
|
BLD-Conference | 7/12/2001 | 7/12/2001 | 7/12/2001 | A | PART |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 7/12/2001 11:40:41 AM w/ bldr...need fire & elec for t/o; verified 3hr doors at bsmt elev shaft entry
|
FIRE-Hydro test above ground | 7/2/2001 | 7/2/2001 | 7/2/2001 | P | PASS |
Joe Tawney
|
|
|
###-#### OK on 4th flr hydro test 7/2/2001 1:01:02 PM
|
FIRE-Sprinkler Rough-in | 6/26/2001 | 6/26/2001 | 6/26/2001 | P | PASS |
Rick Jackson
|
|
|
Doug ###-#### r/i okay to cover 6/26/2001 10:48:06 AM
|
BLD-Other | 6/22/2001 | 6/22/2001 | 6/22/2001 | A | FAIL |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 06/22/2001 at 07:27:07. Contact: ###-####. need wires pods, firecaulk corridor 6/22/2001 12:11:11 PM
|
BLD-Other | 6/20/2001 | 6/21/2001 | 6/21/2001 | A | NR |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 06/20/2001 at 14:55:28. Contact: ###-####.
|
BLD-Framing/Rough-in | 5/9/2001 | 5/9/2001 | 5/9/2001 | A | PART |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 5/9/2001 10:58:25 AM ok to usr frt wood at door/window openings w/i assy
|
BLD-Conference | 5/1/2001 | 5/1/2001 | 5/1/2001 | P | PASS |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 05/01/2001 at 08:38:52. Contact: ###-####. w/ contractor, ok to use frt wood within walls 5/1/2001 4:10:48 PM
|
BLD-Wall cover | 4/25/2001 | 4/26/2001 | 4/26/2001 | A | PART |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 04/25/2001 at 15:21:28. Contact: ###-####.complete firestops & submit detail for tunnel...ok to cover 4/26/2001 12:24:43 PM
|
BLD-Wall cover | 4/19/2001 | 4/19/2001 | 4/19/2001 | P | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 04/19/2001 at 11:11:01. Contact: ###-####. top of corridor ceilling only. 4/19/2001 3:01:59 PM
|