Permit Number | BLD01-00951 |
Status | Finaled |
Name |
SPANGLER BROS., INC. AUTO BODY REPAIR
|
Site Address |
11650 W FAIRVIEW AVE
|
Project Name | |
Customer Number | |
ePlanReview | No |
Description |
*SPANGLER BROS. AUTO BODY SHOP* Within the existing Auto Body Shop, constructed in Ada County, 1979 and classified as an "H-2" occupancy; to install a piece of equipment manufacutered by "Nova-Verta", referred to as a prep station booth with floor plenum mechanical exhaust system and Dry Chem Fire Suppression System. To remove a 25' x 17 ' area of the existing concrete floor slab; excavate to a depth of 36" +/-; install compacted fill, pour perimeter concrete footings, walls, reinforced concrete floor system with thickened edge and interior bearing footings at columns; install steel pipe columns and baseplates; weld to steel beams; weld metal deck to beams; place rebar and pour new 6" floor slab; leaving the down flow air plenum below the new structural support floor system; all per approved plans and engineered details. SPECIAL INSPECTION REQUIRED PER STRUCTURAL ENGINEERS SPECIFICATIONS & PRODUCT EVALUATION SERVICES REPORTS, AS NOTED ON PLANS. A "Letter of Completion / Compliance" is required for this project as evidence of code compliance & inspection approval before the area is allowed to be used for any purpose or use. All per approved plans to include red-line notes on plans, attached plan review comments and engineering. PC#01-322/drs
|