Permit Information
Permit NumberBLD01-00955
StatusFinaled
Name PAM OIL CO / ROB STAPLEY
Site Address 1051 W BOEING ST
Project Name 
Customer Number 
ePlanReviewNo
Description
*PAM OIL CO.* To install Steel Storage Racking within existing warehouse per engineered details. Being installed in conjunction with BLD99-00711, Tenant Improvement for purpose of obtaining a Certificate of Occupancy when both permits (racks & T.I.) have been finaled. Install plaques per code / engineering, to identify allowable maximum loads for each load storage rack unit. Location and installation to be per floor plan layout by Matt Rhees, Cole | Assoc. architect, and the structural engineering, Sal E. Fateen, Seizmic Material Handling Engineering; Bryce Stapley, Stapley Engineering (copy attached). A " Letter of Completion / Compliance" required as evidence of having received final inspection and approval for racking installation. Height of specific products for storage to maintain "S1" occupancy classification SHALL be maintained per the T.I. plan currently under review & Jim Call, F.P.E. call out per Fire Code. NOTE: Hazardous Materials SHALL NOT exceed quantities allowed per Tbls. 3-D & 3-E, 1997 UBC & per 1997 UFC. PC#01-323/drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/27/20019/27/20019/27/2001PPASS
DetailsJim Storey
###-#### final ok cathy to issue l/c. 9/27/2001 2:16:32 PM
BLD-Final8/30/20018/30/20018/30/2001PPART
DetailsJim Storey
Added by Inspector: 301 On 8/30/2001 3:58:10 PM temp ok no use of non compliant stair and racks in blocked off area only one area. stair and end gaurds ordered.
FIRE-Final Inspection8/30/20018/30/20018/30/2001PPASS
DetailsRick Jackson
Added by Inspector: 409 On 8/30/2001 3:54:46 PM
FIRE-Final Inspection8/23/20018/24/20018/24/2001AFAIL
DetailsJoe Tawney
###-#### rob Final Fail racks not installed per approved plan 8/24/2001 12:30:28 PM
BLD-Framing/Rough-in8/23/20018/23/20018/23/2001PFAIL
DetailsJim Storey
1. (Stairway rise and run) The rise of steps and stairs shall not be less than 4 inches nor more than 7 inches. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. Except as permitted for circular, winding, and spiral stairways, the run shall not be less than 11 inches as measured horizontally between the vertical planes of the furthermost projection of adjacent treads or nosings. Stair treads shall be of uniform size and shape, except the largest tread run within any flight of stairs shall not exceed the smallest by more than 3/8 inch. (1997 UBC 1003.3.3.3) Note the exception to tread and riser dimensions for private stairways and stairways to unoccupied roofs and. Also, note the exception to dimensions of risers adjoining a sloping public way. need per pln on one stair approved by planreview not per ubc. 2 3/8 anchor bolts must be replaced to 1/2 x 3 1/2 per engineering 4. saftey clips required on beams.5.barrior post protection at ends of racks in forklift route 6. handrail 34 to 38. 6. fire insp required. 8/23/2001 3:16:51 PM
BLD-Aging Inspection8/16/20018/16/20018/16/2001 PASS
DetailsJim Storey
wip 8/23/2001 3:19:03 PM