Permit Information
Permit NumberBLD01-01398
StatusFinaled
Name TRUAX COMPANY
Site Address 2248 E SOLITUDE CT
Project NameHILLSIDE
Customer Number 
ePlanReviewNo
Description
To construct a 2589 sq. ft. two story single family dwelling with a 1901 sq. ft. unfininshed daylight basement, a 972 sq. ft. attached three car garage, a 142 sq. ft. covered entry porch and a 350 sq. ft. concrete patio with a 350 sq. ft. above grade covered deck sytem at rear of structure per approved plans, all engineering/red-lining and attached requirement lists. (1st floor 1950 sq. ft.)(2nd floor 639 sq. ft.) Note: Seperate permits will be required to finish basement. This lot is located within a hillside area and is subject to the hillside ordinances. Class "A" roof system and defensible space will be maintained. Structure will require the installation of a NFPA 13D fire sprinkler system as regulated by the Fire Department. The sprinkler flow alarm shall be attached to the residence smoke detection system. PC #412 DJO
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/18/20024/19/20024/19/2002APASS
DetailsTom Arcoraci
JEFF ###-#### ok for letter of comp after ok from terry records on hillside requirements 4/19/2002 10:46:33 AM
BLD-Grading Inspection4/19/20024/19/20024/19/2002 BOND
DetailsRita DeYoung
Final grading and drainage has been approved with bond for retaining wall and revegetation of this lot and lots on each side.
BLD-Final4/17/20024/18/20024/18/2002ANR
DetailsTony Young
440--4579
need hillside signed off, no inspection made 4/18/2002 11:56:49 AM
BLD-Final4/18/20024/18/20024/18/2002PFAIL
DetailsTony Young
440--4579 4/18/2002 11:22:01 AM
c/n posted/// need hillside, guard rail compliance, firewall seal 4/18/2002 2:14:56 PM
BLD-Energy code compliance12/12/200112/13/200112/13/2001APASS
DetailsTony Young
###-#### jeff
BLD-Energy code compliance12/10/200112/12/200112/12/2001PPART
DetailsTony Young
JEFF ###-####
some corrections still to do 12/12/2001 4:02:22 PM
FIRE-Sprinkler Rough-in12/12/200112/12/200112/12/2001APART
DetailsRick Jackson
Added by Inspector: 409 On 12/12/2001 10:29:46 AM okay to cover
FIRE-Sprinkler Rough-in12/10/200112/10/200112/10/2001AFAIL
DetailsRick Jackson
Added by Inspector: 409 On 12/10/2001 10:29:25 AM need tenting completed prior to cover ceiling
BLD-Framing/Rough-in12/6/200112/7/200112/7/2001AFAIL
DetailsTony Young
###-#### JEFF
c/n posted, ok to insulate 12/7/2001 11:59:36 AM
BLD-Conference11/13/200111/14/200111/14/2001APASS
DetailsTony Young
###-#### JEFF
frame issues, ok 11/14/2001 2:43:20 PM
BLD-Conference11/14/200111/14/200111/14/2001PPASS
DetailsTony Young
###-#### jeff 11/14/2001 11:43:29 AM
frame walk through 11/14/2001 2:44:04 PM
BLD-Framing/Rough-in10/29/200110/29/200110/29/2001PPART
DetailsTony Young
###-#### JEFF
ext. shear ok 10/29/2001 2:27:47 PM
BLD-Footing9/6/20019/6/20019/6/2001PPART
DetailsTony Young
ready at 2 ###-####
wip, int basement ftgs, ok after verbal corrections 9/6/2001 1:43:54 PM
BLD-Foundation7/31/20017/31/20017/31/2001PPART
DetailsTony Young
###-####
verbal warnings, ok 7/31/2001 2:28:45 PM
BLD-Grading Inspection7/19/20017/19/20017/19/2001 PASS
DetailsRita DeYoung
The footing subgrade has been approved by the geotechnical engineer.
BLD-Footing7/17/20017/18/20017/18/2001APART
DetailsTony Young
dane ###-####
ok pending more paper work in future, verbal ok from Bob @ strata testing 7/18/2001 11:43:11 AM
BLD-Footing7/16/20017/16/20017/16/2001ANR
DetailsTony Young
Scheduled by a contractor via Hello! on 07/16/2001 at 07:23:16. Contact: ###-####.